VT-HACD-DPQ-1-2X-V0-1-D-0 Bosch Rexroth Indramat
MPN: R901054718
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat VT-HACD-DPQ-1-2X-V0-1-D-0 is part of the VT-HACD Digital Axis Controllers series and weighs 0.2 kilograms. This controller features a DeviceNet bus interface, operates at 24 VDC, and supports a maximum of 32 controller cards. It comes with a DIN 41612 Design G connector and has a current consumption of 150 mA.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VT-HACD-DPQ-1-2X-V0-1-D-0 digital axis controller card is produced by Bosch Rexroth Indramat for the VT-HACD Digital Axis Controllers series. The board, identified by part number VT-HACD-DPQ-1-2X-V0-1-D-0, is intended for mounting in a Eurocard frame and provides closed-loop command processing in industrial automation systems. It serves as a central computing element that receives fieldbus and analog references, executes control algorithms, and issues drive signals to external valve amplifiers or inverters, enabling accurate axis positioning without an integrated output stage.
The controller follows the Eurocard form factor with dimensions of 100 x 160 mm. It requires a stable supply of 24 VDC, and the electronics draw about 150 mA, which keeps heat dissipation low inside compact enclosures. Field wiring connects through a 64-pole male multipoint connector that meets the DIN 41612 Design G profile for rack systems. Internal logic executes every 2 ms, and this scan period sets the closed-loop update rate. An analog reference voltage window of ±10 V is provided, and the board’s digital and reference outputs are limited to 30 mA so they can interface directly with high-impedance loads.
Communication with supervisory controllers is handled through the DeviceNet bus, while a service port using RS-232 supports local setup software. Up to 32 axis controller cards can share the local backplane, and cable runs may extend to 280 m before signal repeaters are needed, allowing separated cabinet sections within the same installation. An onboard fuse rated at 4 A time-lag safeguards the 24 V feed against overload conditions. Because the card does not include a valve output stage, it relies on external power amplifiers for final actuation. The assembly weighs 0.2 kg, and the absence of heavy heat sinks keeps the total depth minimal, which helps in high-density rack layouts.
Frequently Asked Questions about VT-HACD-DPQ-1-2X-V0-1-D-0:
Q: What type of bus interface does the VT-HACD-DPQ-1-2X-V0-1-D-0 use?
A: The VT-HACD-DPQ-1-2X-V0-1-D-0 controller uses a DeviceNet bus interface for communication.
Q: What is the operating voltage of the VT-HACD-DPQ-1-2X-V0-1-D-0 controller?
A: This controller requires a 24 VDC operating voltage for proper use.
Q: What is the maximum local bus length for the VT-HACD-DPQ-1-2X-V0-1-D-0?
A: The maximum length supported for the local bus is 280 meters.
Q: What fuse rating is specified for the VT-HACD-DPQ-1-2X-V0-1-D-0?
A: A 4 A time-lag fuse is used with this axis controller for circuit protection.
Q: How much digital output current does the VT-HACD-DPQ-1-2X-V0-1-D-0 provide?
A: The digital output current available on this controller is 30 mA.