VT-HACD-DPQ-1-2X-V0-1-0-0

  • {{ 'Rated ' + avg.toFixed(1) + ' (' + ratingCount + ' total ratings)' }}
  • {{ message }}
Rexroth, Indramat, Bosch Digital Injection and Ejector Controller in the VT-HACD Series. This Digital Injection and Ejector Controller features a Factory Assigned Control Loops, Bus Interface of Without Option, and Device Type of Basic Device.

VT-HACD-DPQ-1-2X-V0-1-0-0

  • {{ 'Rated ' + avg.toFixed(1) + ' (' + ratingCount + ' total ratings)' }}
  • {{ message }}
Rexroth, Indramat, Bosch Digital Injection and Ejector Controller in the VT-HACD Series. This Digital Injection and Ejector Controller features a Factory Assigned Control Loops, Bus Interface of Without Option, and Device Type of Basic Device.

Warranty
1 Year Wake Industrial Warranty Included
Shipping
Worldwide shipping via DHL, UPS, and Fedex
Exchange
Call to find out about our exchange credit for your defective unit.
Sell Us Your Surplus
Have a VT-HACD-DPQ-1-2X-V0-1-0-0 to sell?
To Speak to a sales representative for pricing and lead time:

Product Description

The VT-HACD-DPQ-1-2X-V0-1-0-0 uses explicit messaging to communicate specific parameters. Parameters are either 2 bytes or 4 byes, which can be defined with the help of transmit and receive screen in the BODAC bus manager. You can configure a maximum of 16 parameters in both DeviceNet Receive screen and DeviceNet Transmit. Both the EDS and the parameter map are required for using the VT-HACD-DPQ-1-2X-V0-1-0-0.

The VT-HACD-DPQ-1-2X-V0-1-0-0 is a class 2 DeviceNet device. You can use Explicit Messaging or Transmit and Receive screens to communicate with the VT-HACD-DPQ-1-2X-V0-1-0-0. To communicate using ‘Explicit Messaging’ you need the following information:

Service 

  • Get single attribute (0E hex)
  • Set single attribute (10 hex)

Class

  • Parameter Object (F)

Attribute

  • Always 1

Instance

  • HACD-DPQ Parameter number (From the memory map) 

You can transfer parameters in the internal data format of the VT-HACD-DPQ-1-2X-V0-1-0-0. The internal data format of the VT-HACD-DPQ-1-2X-V0-1-0-0can be converted into the engineering units on its PLC side. You can monitor parameter limits on its PLC side. You have to define the parameters at the PLC side which you have defined in Transmit and Receive screen.

The following parameters have to be transferred:

Data to the HACD-DPQ:

4 Byte INJ. POSITION 4: BUS ID=1013

2 Byte INJ. VELOCITY 1: BUS ID=1292

4 Byte HOLDING: TIME 1: BUS ID=952

Data from the HACD-DPQ:

4 Byte POSITION FB:  BUS ID=2755

4 Byte PRESSURE FB   : BUS ID=2757

2 Byte DISCRETE OUTPUTS:  BUS ID=2782

While configuring the DeviceNet, you have to select the DeviceNet screen which is located in the dropdown menu of its main window. When configuring the ID, you have to ensure every DeviceNet is device is connected to the bus with a unique ID.

  • VT HACD DPQ 1 2X V0 1 0 0
  • VT HACD-DPQ-1-2X/V0/1-0-0
  • VT-HACD-DPQ-1-2X/V0/1-0-0
  • VT-HACD-DPQ-1-2X/VO/1-O-O
  • VTHACDDPQ12XV0100

VT-HACD-DPQ-1-2X-V0-1-0-0 Technical Specifications

Product: VT-HACD
Controller Card Type: Digital Injection and Ejector Controller
Control Loops: Factory Assigned
Component Series: 20 to 29
Bus Interface: Without Option
Display: With Display
Device Type: Basic Device
Valve Output Stage: Without