The VT 5041-24/1-0V IO card operates at 24 V DC with a current consumption of 0.6 A, supports analog command pressures ranging from 0–10 V, and offers a signal adjustment frequency of 5.4 kHz. Designed as part of the VT-5000 IO Cards series by Bosch Rexroth Indramat, it features Euro-card dimensions of 100 x 160 mm.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VT 5041-24/1-0V IO Card is manufactured by Bosch Rexroth. It belongs to the VT-5000 IO Cards series. It is a suitable and reliable solution for a number of industrial automation applications.
The VT 5041-24/1-0V IO card is compatible with swivel angle sensors, specifically the IW9 standard which is likely used to detect the angular position of a rotating part. It supports dual control of which one is based on hydraulic pressure and another is based on swivel angle. It can switch control or routing between two separate hydraulic volumes which means it's suitable for managing systems that have two different pressure zones or circuits. The module includes a function to compensate for hydraulic leakage which is based on pressure and can be enabled or disabled (switchable). To activate or enable the card (via a PLC or external controller), the voltage must be greater than 12V and it likely uses a digital input to determine when the device should be active. It also includes a built in display which shows real-time values (like pressure or angle), system status and error messages etc.
The VT 5041-24/1-0V IO card is designed to work within a voltage window between 21V and 35V. The normal operating current draw is 0.6 amps, but under peak load or startup it can go up to 1.25 amps. The physical electrical connection is made via a 32-pin DIN connector of type D. It is rated to operate reliably within standard industrial temperature conditions, i.e., 0 to 50°C. It is compliant with international standards such as EN 60068-2 and IEC 68-2 for environmental and mechanical stress testing. The total mass of the IO card is 190 grams.
Frequently Asked Questions about VT 5041-24/1-0V:
Q: How does leakage compensation improve hydraulic system performance in the VT 5041-24/1-0V card?
A: Leakage compensation ensures consistent pressure delivery by offsetting internal losses. This results in more stable operation and improved accuracy in demanding applications.
Q: Why is dual control (pressure and swivel angle) important in VT 5041-24/1-0V?
A: Dual control allows for precise synchronization between force and positioning. This is essential for high-performance hydraulic or motion systems.
Q: What role does the enable input (V > 12V) play in system safety?
A: The enable input prevents unintentional activation by requiring a deliberate voltage signal. This enhances operational safety and control flexibility.
Q: Why is the VT 5041-24/1-0V designed with a peak current of 1.25 A?
A: The higher peak current supports startup loads or brief spikes. This helps prevent system resets or voltage drop issues during dynamic operations.
Q: How does compliance with EN 60068-2 benefit the VT 5041-24/1-0V in the field?
A: Compliance ensures the IO card withstands harsh environments like vibration, humidity, and shock. This improves longevity and reliability in industrial setups.