4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

VT-5005 S10 Bosch Rexroth Indramat

In-Stock, Ships 1-2 Days

Current response time:
3 Minutes 12 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat VT-5005 S10 is an IO card from the VT-5000 IO Cards series, measuring 100 by 160 millimeters. It operates at 24 VDC and supports a maximum solenoid current of 1.8 Amps with a solenoid resistance of 5.4 Ohms. The card uses a 32-pin DIN 41612 Form D connection and has a regulated voltage of ±9 V with a fuse rated at 2.5 Amps.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VT-5005 S10 is an input/output card produced by Bosch Rexroth Indramat for the VT-5000 IO Cards series. It installs in a 3U rack and links motion controllers to proportional valve coils, pressure transducers, and feedback sensors. By generating stable reference rails and monitoring return signals, the board allows a PLC to command hydraulic actuators with consistent accuracy while keeping higher-current loops away from delicate logic circuitry.

The board follows the Eurocard format and measures 100 × 160 mm. It slides into a backplane through a 32-pin DIN 41612 Form D connector that carries power, commands, and diagnostic signals. A single 24 VDC rail supplies the onboard regulators and valve drivers. A square-wave generator operating at 2.5 kHz ±10% provides the carrier for pulse-width modulation, allowing the downstream coils to receive a smooth average current. The driver section provides a fixed amplitude of 5 V for the reference and monitoring circuits, allowing linear comparison of command and feedback voltages. Four differential inputs accept ±9 V signals, while a fifth channel accepts ±10 V to accommodate common motion-control outputs. Measurement jacks have an impedance of 100 Ω, allowing signals to be checked without disturbing the loop, and the regulated ±9 V supply maintains deviations within ±1% to preserve calibration.

The solenoid stage can deliver up to 1.8 A ±20% to coils with a resistance of 5.4 Ω, enabling fast spool movement without thermal overload. External analog devices, such as LVDTs or pressure sensors, may draw up to ±25 mA from the card’s excitation outputs. The enable line recognizes logic-high signals above 8.5 V to activate those supplies. Continuous operation is permitted at temperatures up to 50 °C. A time-delay 2.5 A fuse protects the power input if a wiring fault causes excessive current.

Ambient Temperature Range
0-45°C
Cable Length
200 meters
Card Size
100 x 160 mm
Command Input 1-4
±9 V
Command Input 5
±10 V
Compliant
Cat6
Connection Type
32-pin DIN 41612 Form D
Connector Type
RJ45
Controlled Voltage
9V
Driver Output Amplitude
5 V
Enable Active Level
>8.5 V
External Load Current
±25 mA
Fuse Rating
2.5 A T
Jacket Material
PVC
Max Bandwidth
1 Gbps
Max Solenoid Current
1.8 A ±20%
Max Transducer Load
30 mA
Maximum Output Current (Solenoid A)
2.2A
Measuring Socket Impedance
100 Ω
Minimum Load Resistance
800 Ω
Operating Temp Max
50 °C
Operating Voltage
24 VDC
Oscillator Frequency
2.5 kHz ±10%
Power Consumption
80 VA
Power Supply (Single-Phase)
24V ± 10% (full-wave rectification)
Power Supply (Three-Phase)
24V - 35V
Regulated Voltage
±9 V ±1%
Shielding
STP (Shielded Twisted Pair)
Solenoid Resistance
5.4 Ω
Valve Compatibility
4WRE6..10 series with spool feedback

Frequently Asked Questions about VT-5005 S10:

Q: What type of connection interface does the VT-5005 S10 IO card utilize?

A: The VT-5005 S10 card uses a 32-pin DIN 41612 Form D connection type.

Q: What is the operating voltage for the VT-5005 S10 card?

A: The VT-5005 S10 operates with a supply voltage of 24 VDC.

Q: What is the maximum solenoid current capacity of the VT-5005 S10?

A: The maximum solenoid current supported by the VT-5005 S10 is 1.8 A ±20%.

Q: What are the command input voltage ranges for the VT-5005 S10 IO card?

A: The command input voltage ranges are ±9 V for inputs 1 to 4, and ±10 V for input 5.

Q: What is the maximum operating temperature for the VT-5005 S10 IO card?

A: The VT-5005 S10 card can operate at temperatures up to 50 °C.

  • vt-5005 s10
  • VT-55 S1
  • VT5005 S10
  • vt5005 s10
  • VT-S005 S10
  • VT-5O05 S10
  • VT-50O5 S10
  • VT-500S S10
  • VT-5005 510
  • VT-5005 SI0
  • VT-5005 S1O
  • VT-SOOS 5IO
  • VT-505 S10
  • VT-5005 S1

Internal Product Review

  • ‘‘The VT-5005 S10 is an IO card engineered for dependable control performance with 24 VDC operation and a 32-pin DIN 41612 Form D connection. Command handling remains flexible with ±9 V inputs on channels 1 through 4 and a ±10 V input on channel 5. A 1.8 A ±20% maximum solenoid current stands out as a strong specification for electrohydraulic control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo