VT 5002 S20

    In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The VT 5002 S20, part of Bosch Rexroth Indramat's VT-5000 IO Cards series, operates at 24 VDC with a current consumption of 0.6 A rated and 1.25 A max. The card features a swivel angle command input of ±10V, a solenoid current of up to 2.5A, and a 5.4 kHz oscillator frequency. It uses a 32-pin male DIN multipoint connector.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Bosch Rexroth manufactured the Analog amplifier module VT 5002 S20. It is designed to be used in industrial automation that needs exact control of signals and outputs. VT 5002 S20 operates with a ±15 V DC supply and provides a solid base for controlling current flow and changing signals.

The VT 5002 S20 analog amplifier module needs about 60 mA per supply line and can handle a ±5% change in the power source. The normal order input is ±10 V differential, and an input impedance of around 100 kΩ can handle it. The amplifier can send out a maximum of ±60 mA per output line and needs an output load of at least 50 Ω. The rise and fall behavior can be managed because the ramp time can be changed from 0.01 seconds to 3 seconds. Additionally, the VT 5002 S20 has a deadband adjustment that can be changed using a special potentiometer. It contains an adjustable ramp generator, signal limiter, strength, and offset potentiometers. A monitor output of ±10 V provides real-time valve current feedback via a test point. Modular control systems that use controlled analog signaling benefit from these properties.

The VT 5002 S20 amplifier is a Euro-card that is 100 mm by 160 mm and has a 32-pin DIN 41612 male connection, type D, for connecting. It cools itself passively through natural airflow. This analog amplifier module functions between 0 and +50 °C and can be stored between –25 and +85 °C. It resists condensation at 5–95% humidity. The VT 5002 S20 includes adjustable feedback and modulation tools for precise control. The VT 5002 S20 can handle commands with different types of input and has built-in tools for ramp generation and signal conditioning.

Analog Command Value Input
Pressure PSOLL: 0...10 V; Re > 50 kΩ
Current Consumption
0.6 A (rated) / 1.25 A (max)
Error Message (low-active)
UB - 3 V (I max = 20 mA); Error U < 1 V
Front Plate Dimensions
Height 3 HE (128.4 mm), Width 5 or 7 TE depending on model
Lower Voltage Limit
21 V
Operating Temperature Range
0°C to 50°C
Operating Voltage
24 VDC +40% -10% (21.6...33.6 V)
Oscillator Frequency
5.4 kHz
Physical Dimensions
Euro-card 100 x 160 mm
Solenoid Current
2.5 A max; Resistance R20 = 2 Ω
Swivel Angle Command Input
Standard ±10 V; Regenerative 0...10 V; Re > 50 kΩ
Type Of Connection
32 pin male multipoint connector, DIN 41612, design D
Upper Voltage Limit
35 V
Weight (electronic Card)
0.19 kg (without display) / 0.21 kg (with display)

Frequently Asked Questions about VT 5002 S20:

Q: Why does VT 5002 S20 use differential input?

A: Differential input improves noise immunity and allows accurate signal processing. VT 5002 S20 supports ±10 V differential command input for reliable control.

Q: Why does VT 5002 S20 require a 50 Ω load?

A: The amplifier requires a minimum load of 50 Ω to ensure stable output and avoid overloading the output current driver.

Q: How does VT 5002 S20 handle output regulation?

A: VT 5002 S20 provides adjustable ramp times and signal limiters that allow precise control over output behavior and voltage transitions.

Q: Does VT 5002 S20 support signal monitoring?

A: Yes, it includes a ±10 V monitor output that provides real-time valve current feedback through a dedicated test point.

Q: Why is deadband compensation in VT 5002 S20 adjustable?

A: Deadband compensation adjustment allows fine-tuning to eliminate signal gaps and enhance control accuracy in analog output systems.