VT 3000 S 34-R5 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat VT 3000 S 34-R5 is part of the VT 3000 Analog Amplifiers series and features a power supply voltage of 24 VDC with a consumption of 30 W. It provides a maximum output current of 800 mA, has 6 contact relays, and includes 4 input potentiometers. The amplifier weighs 0.15 kg and supports a fuse rating of 2.5 A.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VT 3000 S 34-R5 analog amplifier module is built by Bosch Rexroth Indramat for use within the VT 3000 Analog Amplifiers series. As a plug-in controller, it converts low-level command voltages into regulated coil currents that drive proportional hydraulic valves, allowing motion sections of an automation cell to follow analog references from a PLC. The card receives setpoints, conditions them through internal electronics, and sends the resulting power-stage output to a valve solenoid, providing closed-loop adjustment without digital conversion.
The board operates from a single 24 VDC ±10% supply and can draw 30 W at full load, so the cabinet rail must cover that margin. Internally, the generator delivers up to 800 mA, which is compatible with coils down to 19.5 Ω, and a 2.5 A fuse clears faults before traces overheat. Command inputs enter through a differential pair that tolerates ±9 V and presents a load of at least 500 Ω, while a second channel reads up to 10 V for fine trimming. A test header maps output current to 1 mV per 1 mA for quick measurement, and four front potentiometers set zero, span, and ramp while six relay contacts provide enable and alarm signaling to the host control system.
During normal operation, the amplifier maintains a baseline bias of 20 mA so valves remain centered against spring forces before process commands arrive. An auxiliary channel accepts a secondary setpoint of ±6 V that can overlay the main reference for remote override. Temperature sensitivity is limited to 0.5‰/K, supporting consistent response as machinery warms from startup to steady state, and the card's mass of 0.15 kg helps it reach thermal equilibrium quickly inside a crowded rack. The calibrated layout keeps troubleshooting straightforward because the test header and potentiometer banks are arranged along the front edge for tool-free access.
Frequently Asked Questions about VT 3000 S 34-R5:
Q: What power supply voltage is required for the VT 3000 S 34-R5 analog amplifier?
A: The VT 3000 S 34-R5 amplifier operates with a power supply voltage of 24 VDC ±10%.
Q: What is the maximum output current provided by the VT 3000 S 34-R5?
A: This model can deliver a maximum output current of 800 mA.
Q: How many contact relays are included in the VT 3000 S 34-R5 amplifier?
A: The VT 3000 S 34-R5 features six contact relays supporting various switching functions.
Q: How many input potentiometers are available on the VT 3000 S 34-R5?
A: The amplifier is equipped with four input potentiometers for adjustment.
Q: What is the fuse rating specified for the VT 3000 S 34-R5 analog amplifier?
A: This amplifier has a fuse rating of 2.5 A for circuit protection.