The Bosch Rexroth Indramat TVM 2.4-050-220/300 is a power supply module in the TVM Power Supply Modules series and weighs 15 kg. It operates with an input voltage of AC 220 V, an input frequency range of 50 to 60 Hz, and uses a built-in blower for cooling. The module delivers a continuous output current of 25 A and supports a DC bus continuous power of 7.5 kW.
Internal Product Review
The TVM 2.4-050-220/300 is a Bosch Rexroth Indramat power supply module with AC 220 V input and 25 A continuous output current. Built-in blower cooling and IP10 protection support stable cabinet operation in drive systems. A 300 V nominal DC bus and 60 kW peak DC bus power make the unit an excellent fit for demanding motion applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The TVM 2.4-050-220/300 is a power supply module built by Bosch Rexroth Indramat for the TVM Power Supply Modules series. It converts three-phase line power into a regulated DC bus that feeds multiple servo inverters, allowing synchronized motion in automated tooling, packaging, and material-handling equipment. Integrated control electronics supervise bus voltage, energy dissipation, and auxiliary rails so the connected drives receive stable power during motoring and regeneration.
The module accepts an input of AC 220 V with a tolerance window of +15 / -10 %, and it operates on plant networks at 50–60 Hz. After rectification and filtering, the internal supply reaches a nominal level of DC 300 V. At this voltage, the unit can source a continuous DC output of 25 A, which corresponds to 7.5 kW of sustained bus power for downstream axis controllers. A built-in blower moves cooling air through the heat sink to manage conversion losses and maintain safe thermal conditions. Control logic draws 550 VA from the line supply, while separate rails provide +15 V at 1.3 A, -15 V at 1.0 A, and 24 V at 8 A for external sensors, relays, and drive electronics.
During rapid deceleration or overhauling loads, the supply can absorb regenerative power peaks up to 60 kW, and its bleeder circuitry dissipates 0.45 kW continuously while handling 14 kWs of returned energy. The module has a maximum power loss of 130 W, and exhaust air is discharged through the blower outlet. The housing carries an IP10 rating, which provides finger-safe protection but no fluid sealing, and the assembly weighs 15 kg, so the mounting panel must support the load. The listed type current of 50 A guides the sizing of fuses, conductors, and busbars for long-term operation in industrial cabinets.