4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

TDA 1.3-050-3-A0D Bosch Rexroth Indramat

MPN: R911275566

Ask for Availability

The Bosch Rexroth Indramat TDA 1.3-050-3-A0D belongs to the TDA Main Spindle Controllers series and has a rated current of 50 Amps with a link circuit rated voltage of 300 VDC. The controller weighs 10.5 kg, uses air cooling inside the control cabinet, and has a digital position command interface. It supports a maximum ambient temperature of 55 degrees Celsius and has a protection type of IP10.

No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The TDA 1.3-050-3-A0D is a Bosch Rexroth Indramat main spindle controller with 50 A rated current and air-inside-cabinet cooling. Vertical mounting and IP10 protection make cabinet integration clean and service access practical in controlled environments. Analog ±10 V command capability supports accurate spindle response, with 35 A continuous effective current serving as a strong performance highlight.

Sell Part Have a part to sell?
Warranty Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The TDA 1.3-050-3-A0D main spindle controller is produced by Bosch Rexroth Indramat within the TDA Main Spindle Controllers series. It governs the torque and rotational speed of machine-tool spindles by converting drive commands into regulated three-phase power. The unit is intended for vertical mounting inside the electrical cabinet and relies on internal cabinet air for cooling. A dedicated 16-bit Digital Position Command interface is available for applications that need numeric position data, and there is no additional encoder input at the controller end, so speed feedback must come through the standard spindle transducer channel.

The controller’s electrical ratings set its continuous operating range. The rated output stage can deliver a continuous line current of 50 A, while the thermal design permits a continuous effective motor current of 35 A under nominal conditions. The link circuit is energized from a DC bus held at 300 VDC, and analog velocity references are accepted over a differential line with a range of analog ±10 V. A separate blower connection rated at 220 VAC supplies the external spindle-motor fan so the internal power section is not loaded with auxiliary ventilation demands, and an internal 15 V test rail limited to 160 mA supports signal diagnostics.

Physical and ambient limits must be considered during installation. The unit has a mass of 10.5 kg, which provides a substantial chassis for conductive heat flow. Operation is permitted up to +55 °C and 1000 m altitude without derating, provided cabinet ventilation follows the stated airflow principle. The housing has an IP10 protection type, so only basic touch protection is provided and the device must remain inside a closed panel. The logic electronics draw auxiliary energy from the 24 V rail and require a load current of 1.2 A; wiring for this supply and the main grounding conductor must follow the minimum 10 mm² cross-section required for safety.

15 V Test Current
160 mA
24 V Load Current
1.2 A
Additional Encoder Input
None
Additional Interface
Digital Position Command (16-Bit)
Blower Supply Voltage
220 VAC
Command Value
Analog ±10 V
Continuous Effective Current
35 A
Controller Weight
10.5 kg
Cooling Principle
Air Inside Control Cabinet
Link Circuit Rated Voltage
300 VDC
Max Altitude
1000 m
Max Ambient Temp
+55 °C
Min Earthing Cable
10 mm²
Mounting Orientation
Vertical
Protection Type
IP10
Rated Current
50 A

Frequently Asked Questions about TDA 1.3-050-3-A0D:

Q: What type of additional interface does the TDA 1.3-050-3-A0D provide?

A: The TDA 1.3-050-3-A0D controller supports a 16-bit digital position command interface for precise position control.

Q: What is the rated current capacity of the TDA 1.3-050-3-A0D spindle controller?

A: This controller delivers a rated current of 50 A, which is suitable for demanding main spindle applications.

Q: How is the TDA 1.3-050-3-A0D main spindle controller cooled?

A: The TDA 1.3-050-3-A0D uses a cooling principle that relies on air circulation inside the control cabinet.

Q: What is the minimum earthing cable size for the TDA 1.3-050-3-A0D controller?

A: This model requires a minimum earthing cable size of 10 mm² to ensure proper electrical grounding.

Q: What is the blower supply voltage specification for the TDA 1.3-050-3-A0D controller?

A: The TDA 1.3-050-3-A0D features a blower supply voltage rated at 220 VAC for effective internal cooling.

  • TDA 130503A0D
  • TDA 1 3 050 3 A0D
  • tda 1.3-050-3-a0d
Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo