TDA 1.1-50-3-API Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911251880
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat TDA 1.1-50-3-API is a main spindle controller from the TDA Main Spindle Controllers series. It has a rated current of 50 Amps, a DC link voltage of 300 VDC, and weighs 10.5 kilograms. The controller is designed with air cooling inside the control cabinet, supports a maximum ambient temperature of 55°C, and features a 15-pin encoder input connector with an output resolution of 360000 increments per revolution.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The TDA 1.1-50-3-API is a main spindle controller produced by Bosch Rexroth Indramat within the TDA Main Spindle Controllers series. The unit serves as a drive interface between an automation system and a machine tool spindle, converting analog velocity commands into precise three-phase power for high-speed machining applications. By integrating encoder feedback and internal control loops, it regulates spindle speed, torque, and position so that machining centers maintain repeatable tolerances during production.
Electrical capability begins with a rated output of 50 A, while continuous operation is sustained at 35 A to match the thermal capacity of the power stage. A stabilized link voltage of 300 VDC feeds the inverter bridge, supplied from a common DC bus that also delivers 15 V at 160 mA for logic circuits and 1.2 A at 24 V for contactors and sensors. The controller accepts a differential speed reference of ±10 V, allowing standard CNC controls to issue velocity setpoints without additional signal conditioning. The blower supply is kept separate from the drive electronics, which helps prevent the cooling circuit from loading the low-voltage control functions.
Axis feedback enters through a 15-pin connector, and the drive retransmits data at 360000 Incr/Rev, enabling external counters to monitor spindle position with fine granularity. Internally, the command path interpolates to 1/4,000,000 Rev, which supports micro-incremental orientation moves such as tool change alignment and accurate spindle positioning at standstill. Forced-air circulation uses air inside the control cabinet, and the required blower runs on 220 VAC so no auxiliary transformer is needed. Installation is limited to 1000 m altitude, 55 °C ambient temperature, and a vertical mounting plane, and the IP10 housing is intended for open-rack ventilation. The chassis weighs 10.5 kg, which should be considered when planning slide-in rack support and handling.
Frequently Asked Questions about TDA 1.1-50-3-API:
Q: What is the rated current of the TDA 1.1-50-3-API spindle controller?
A: The rated current for the TDA 1.1-50-3-API spindle controller is 50 A.
Q: What mounting orientation is required for the TDA 1.1-50-3-API?
A: The TDA 1.1-50-3-API must be mounted vertically for proper installation.
Q: What is the DC link voltage used by the TDA 1.1-50-3-API?
A: This controller operates with a DC link voltage of 300 VDC.
Q: How is the TDA 1.1-50-3-API spindle controller cooled?
A: The cooling principle for this device is air inside the control cabinet.
Q: What type of connector does the TDA 1.1-50-3-API use for encoder input?
A: A 15-pin connector is used for the encoder input on this model.