TBM 1.2-40-W1-220/S100 Bosch Rexroth Indramat

MPN: R911234737

No Tariffs On US Orders
  • Rated 4.5 (44 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Available, Ships in 1-2 weeks

Preparing your secure checkout page...

The Bosch Rexroth Indramat TBM 1.2-40-W1-220/S100 is a bleeder module from the TBM Bleeder Modules series with a peak power of 40 kW and blower voltage of 220 VAC. It features air internal cooling with an 80 mm cooling clearance and dimensions of 390 mm in height, 208 mm in width, and 105 mm in depth.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The TBM 1.2-40-W1-220/S100 bleeder module is produced by Bosch Rexroth Indramat within the TBM Bleeder Modules series. Installed across the DC link of an Indramat converter, it dissipates surplus regenerative energy as heat and keeps the bus voltage within safe limits during braking cycles in industrial automation cells. It acts as an auxiliary load that protects connected power sections from overvoltage trips during rapid deceleration or repeated load reversals. This role is especially useful on axes that return energy to the drive when a moving load is slowed or reversed. In applications with frequent starts and stops, it helps prevent the DC link from rising faster than the converter can tolerate.

At the electrical interface, the resistor stack supports a peak dissipation of 40 kW, enabling short-term energy absorption when a servo axis returns power to the drive. An auxiliary centrifugal blower powered at 220 VAC pushes cooling air through internal channels, and its supply conductors land on terminals that accept wire up to 2.5 mm². Thermal management uses internal air cooling, so the installation requires a clearance of 80 mm above and below the housing for unobstructed airflow. This airflow helps carry heat away from the resistor assembly during repeated braking events. The air path should remain open, since blocked space above or below the housing reduces heat removal. Control terminals share the same wire capacity for signal leads, and the factory jumper between the resistor bed and the power bus can be extended only to the specified 1 m maximum lead length.

Overall depth is limited to 105 mm, while the front face measures 208 mm wide and 390 mm high, allowing placement beside standard drive controllers on a 400 mm panel. The shallow depth helps the module fit enclosures where rear clearance is limited. Power conductors that carry brake energy connect to cage clamps rated for 10 mm² wire, which offers lower impedance than the smaller control leads. The tall front face leaves room for vertical terminal access and adjacent component placement. Terminal orientation aligns with the airflow path, minimizing cable obstruction and helping maintain the required clearance around the housing.

Blower Terminal Max
2.5 mm²
Blower Voltage
220 VAC
Control Terminal Max
2.5 mm²
Cooling Clearance
80 mm
Cooling Mode
Air Internal
Depth
105 mm
Height
390 mm
Lead Length Max
1 m
Peak Power
40 kW
Power Terminal Max
10 mm²
Width
208 mm
  • TBM1240W1220/S100
  • TBM 1 2 40 W1 220/S100
  • tbm 1.2-40-w1-220/s100

Frequently Asked Questions about TBM 1.2-40-W1-220/S100:

Q: What is the peak power capability of the TBM 1.2-40-W1-220/S100 bleeder module?

A: The TBM 1.2-40-W1-220/S100 supports a peak power rating of 40 kW.

Q: What is the required blower voltage for the TBM 1.2-40-W1-220/S100?

A: This bleeder module requires a blower voltage of 220 VAC for operation.

Q: How much cooling clearance does the TBM 1.2-40-W1-220/S100 require?

A: The recommended cooling clearance for this module is 80 mm to ensure proper airflow.

Q: What is the cooling mode implemented in the TBM 1.2-40-W1-220/S100?

A: Air internal mode is used for cooling in the TBM 1.2-40-W1-220/S100 bleeder module.

Q: What is the maximum lead length allowed for the TBM 1.2-40-W1-220/S100?

A: The maximum allowable lead length for power connections is 1 meter on this module.


Internal Product Review

  • ‘‘The TBM 1.2-40-W1-220/S100 is a bleeder module engineered for reliable braking energy dissipation, with 40 kW peak power and a 220 VAC blower supply. Air-internal cooling supports consistent thermal performance, and 10 mm² power terminals help streamline panel integration. An excellent fit for demanding drive systems where controlled heat management is critical.’’