R-IB-IL DOR-LV-SET Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911291260
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat R-IB-IL DOR-LV-SET is part of the R-IB Interface Modules series and features a single terminal width of 12.2 mm. It has a relay-bus test voltage of 4 kV at 50 Hz for 1 minute, with analog and logic supply passed through and separated potentials. Clearance and creepage distances are both at least 5.5 mm.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The R-IB-IL DOR-LV-SET module is an interface element produced by Bosch Rexroth Indramat for the R-IB Interface Modules series. It transfers relay commands from the system bus to field wiring and mounts on a DIN rail inside distributed control cabinets. In industrial automation, the part forms a compact relay-output set that enables a controller to energize or de-energize external loads while keeping bus logic and load circuits electrically isolated. This arrangement is useful when control signals must switch contactors, lamps, or other field devices without connecting those loads directly to the bus electronics. It is intended for distributed I/O layouts where output switching must fit into narrow cabinet spaces.
The module's analog and logic supply is passed through, so no local power conversion is required when it is inserted between adjacent terminals. Safe spacing is maintained by a minimum clearance of ≥ 5.5 mm between conductive parts, reducing the risk of arcing inside crowded cabinets. The relay path has been verified with a dielectric test of 4 kV, 50 Hz for 1 minute, confirming insulation strength across the output circuit. Each output occupies only 12.2 mm of rail width, allowing dense packing of multiple sets on the same rail section. The module has no diagnostic indicators, so any required status monitoring must be handled by the host controller.
When several voltage domains share a panel, the module aids segregation because its other potentials are declared as separated from the internal relay bus. Surface tracking resistance is supported by a creepage distance of ≥ 5.5 mm, helping prevent conductive deposits from bridging outputs in humid environments. This layout supports installation beside other terminal modules where relay channels and control voltages are routed through the same cabinet section. The separation between the relay bus and other potentials is useful in cabinets where control-level signals and switched load circuits run side by side over short distances. It also helps keep neighboring circuits apart when multiple output groups are arranged in close proximity.
Frequently Asked Questions about R-IB-IL DOR-LV-SET:
Q: What is the width of each terminal on the R-IB-IL DOR-LV-SET interface module?
A: The R-IB-IL DOR-LV-SET has a single terminal width of 12.2 mm for compact installations.
Q: Are diagnostic indicators included in the R-IB-IL DOR-LV-SET?
A: This module does not feature any diagnostic indicators.
Q: How is the analog and logic supply handled in the R-IB-IL DOR-LV-SET?
A: Analog and logic supplies are passed through in the R-IB-IL DOR-LV-SET model.
Q: What are the minimum clearance and creepage values for the R-IB-IL DOR-LV-SET?
A: The minimum clearance and creepage distance for this module is 5.5 mm.
Q: What is the relay-bus test voltage rating for the R-IB-IL DOR-LV-SET interface module?