The PSI6300.228L1 medium frequency inverter by Bosch Rexroth has a line voltage rating of 400 VAC to 480 VAC. This inverter delivers a medium frequency output voltage and a DC welding current. It has a clocking frequency of 1 kHz.

✓ In-Stock!

Wake Industrial LLC is not an authorized distributor of this product.

PSI6300.228L1

  • Rated 4.5 (38 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
  • MPN: R911311302
    In-Stock, Ships 3-5 Days
  • Call for Expedited Shipping and Product Condition Options

The PSI6300.228L1 medium frequency inverter by Bosch Rexroth has a line voltage rating of 400 VAC to 480 VAC. This inverter delivers a medium frequency output voltage and a DC welding current. It has a clocking frequency of 1 kHz.

Warranty
1-year-warranty Wake Industrial Warranty
Shipping
DHL Logo FedEx Logo
UPS Logo Freight Logo
DHL Logo FedEx Logo UPS Logo Freight Logo
Payment
Visa Logo AmEx Logo
Mastercard Logo Wire transfer Logo
Visa Logo AmEx Logo Mastercard Logo Wire transfer Logo
To Speak to a sales representative for pricing and lead time:

Product Description

The PSI6300.228L1 Bosch Rexroth medium frequency inverter has a robust design. This frequency inverter is equipped with a control function. The product deploys an air cooling mechanism. This device should be operated only after reading its documentation. The unit is used with a welding transformer for resistance welding of metals. It complies with low voltage and EMC directives. This inverter is not meant to be operated with the doors of its control cabinet left open. The product is recommended to be operated by personnel skilled in drive technology. This device has a hot surface when it is in use. The unit can trigger unfavorable consequences when it is not operated as intended. It produces strong magnetic fields during the operation phase. This inverter is installed along with a power supply in a control cabinet with at least an IP 54 protection rating. The product should be operated at a mains voltage that is identical to the line voltage mentioned on its type plate. This device is meant to be put to use after wearing safety apparel such as protective gloves and goggles as well as flame-retardant clothes to avoid the effects of welding splashes. The frequency inverter supports a maximum ambient operating temperature of 45 °C. This unit may get overheated because of insufficient cooling. Its operation must take place under forced-air cooling conditions. The product supports a PROFIBUS I/O connection. This device is meant to be operated in residential areas only after the necessary permit has been obtained. This device should be connected only after switching off the power supply. The unit supports only Type B residual current devices on its mains side.

PSI6300.228L1 Technical Specifications

Series: PSI
Operating Climatic Category: 3K3
Maximum Ambient Operating Temperature: 45 °C
I/O Field Bus Interface: PROFIBUS
Version Number: 28
Welding Current: 6 kA to 36 kA
Protection Class: IP 20
Cooling: Air
Temperature Monitoring: Yes
Maximum Installation Elevation: 2000 m Above Sea Level

Frequently Asked Questions about PSI6300.228L1


Q: What is the protection rating of the control cabinet in which the PSI inverter is mounted?

A: The protection rating of the control cabinet in which the PSI inverter is mounted is IP 54.

Q: What is the operating climatic class of the PSI inverter?

A: The PSI inverter has a 3K3 climatic class according to EN 60721-3-3 specifications.

Q: What is the wait period before working on the PSI inverter after turning off the power supply?

A: The wait period before working on the PSI inverter after turning off the power supply is 5 minutes.

Q: What is the lifespan of the battery of the weld timer of the PSI inverter?

A: The lifespan of the battery of the weld timer of the PSI inverter is approximately two years.

Q: How should the three terminals of the PSI inverter be connected?

A: The three terminals of the PSI inverter are connected to the three system phases.