4.94 based on 222 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

PSI65C0.733-W1 Bosch Rexroth Indramat

Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat PSI65C0.733-W1 is a medium frequency inverter from the PSI Frequency Inverters series. It features a maximum output current of 2400 Amps, supports a mains voltage range of 400 to 480 VAC, and uses water cooling with a flow rate of 10 liters per minute. The inverter has an IP20 protection rating, a clock frequency of 1 kHz, and a maximum cable size of 120 square millimeters.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The PSI65C0.733-W1 medium-frequency inverter is manufactured by Bosch Rexroth Indramat within the PSI Frequency Inverters series. It serves as the power stage in industrial automation cells that require controlled medium-frequency energy, such as induction heating stations or surface-treatment baths. The unit modulates incoming AC power through an integrated converter. Its logic section maintains waveform quality while coordinating start, stop, and ramp functions with plant controllers.

The power section accepts a three-phase supply of 400 to 480 VAC and switches it at a carrier rate of 1 kHz to create a stable medium-frequency output. The maximum output current is 2400 A, while an MOV network provides overvoltage suppression on the DC link. Water is the designated cooling medium, and the heat exchanger requires a flow rate of 10 L/min. The cabinet provides a protection level of IP20 when installed in a closed electrical room. Thermal data indicate 100 W of basic cabinet loss and up to 4400 W of heat from the liquid-cooled heat sink under full demand. The control electronics operate from a 24 V DC logic rail, and timing commands are distributed over the internal Ethernet timer channel.

The nominal system current is rated at 660 A, representing the continuous operating load on bus bars secured with M10 terminal bolts. Maximum enclosure heat dissipation is limited to 850 W, allowing the unit to be installed in cabinets that share forced-air plenums with other drives. Water must enter the heat exchanger below 30 °C, because higher inlet temperatures reduce its heat-removal capacity. The maximum conductor cross section at the power studs is 120 mm², and the matching water manifold uses an M16 × 1.5 thread. The inverter tolerates ambient temperatures up to 45 °C and withstands up to 120 kA on the secondary side during fault clearing.

Basic Cabinet Loss
100 W
Climatic category
3K3 according to EN 60721-3-3
Clock Frequency
1 kHz
Cooling Method
Water Cooled
Cooling Water Flow
10 l/min
Degree Of Protection
IP 20
Integrated power supply unit Output current
max. 2 A
Integrated power supply unit Output voltage
24 VDC
Logic Supply Voltage
24 V DC
Mains frequency
50 or 60 Hz
Mains Voltage
400 - 480 VAC
Max Ambient Temp
45 °C
Max Cabinet Loss
850 W
Max Cable Size
120 mm²
Max Cooling Loss
4400 W
Max Output Current
2400 A
Max Secondary Current
120 kA
Max Water Inlet Temp
30 °C
Max. cooling losses
420 W
Nominal System Current
660 A
Overvoltage Protection
MOV
Product Type
Medium Frequency Inverter
Temperature range Operation
+10 -+55 ºC
Temperature range Storage / transport
-25 - +70 ºC
Terminal Bolt Size
M10
Timer Type
EtherNet
Water Connection
M16 x 1.5
Weight
approx. 25 kg

Frequently Asked Questions about PSI65C0.733-W1:

Q: What mains voltage does the PSI65C0.733-W1 frequency inverter support?

A: The PSI65C0.733-W1 inverter has a mains input voltage range of 400 to 480 VAC.

Q: What is the maximum output current for the PSI65C0.733-W1 inverter?

A: This frequency inverter offers maximum output current of 2400 A.

Q: What cooling method is employed by the PSI65C0.733-W1 inverter?

A: The PSI65C0.733-W1 uses water cooling with a required flow rate of 10 liters per minute.

Q: What is the maximum ambient temperature for the PSI65C0.733-W1 inverter?

A: The inverter operates reliably at ambient temperatures up to 45°C.

Q: What is the degree of protection rating for the PSI65C0.733-W1 frequency inverter?

A: The device has an IP 20 degree of protection, meaning it is protected against solid objects over 12 mm but not against water entry.


Internal Product Review

  • ‘‘The PSI65C0.733-W1 is a medium frequency inverter with water-cooled operation suited to continuous industrial duty. Support for 400 - 480 VAC mains voltage and 660 A nominal system current gives the design strong application range in high-load installations. A 2400 A maximum output current stands out as the key performance advantage.’’