4.94 based on 222 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

PSI63C0.757-L2 Bosch Rexroth Indramat

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The PSI63C0.757-L2 is a well-executed medium frequency inverter with air-cooled operation and IP20 protection. The 480 to 690 VAC mains voltage range and 110 A nominal mains current support confident integration in demanding drive systems. A 1000 Hz sequence frequency stands out as a strong performance advantage.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The PSI63C0.757-L2 frequency inverter is produced by Bosch Rexroth Indramat as part of the PSI Frequency Inverters series. Within an assembly line, this medium-frequency inverter converts high-voltage three-phase mains power into a controlled output for induction heating, welding, or other processes that need adjustable medium-frequency power. It installs inside a control cabinet and connects to Ethernet timers so sequence commands can be synchronized with other motion or process controllers.

This cabinet-mounted unit carries a protection rating of IP20, so live parts are shielded from touch, but the enclosure is not sealed against dust. The input section accepts a mains range of 480–690 VAC, allowing direct connection to common 600-volt plant supplies. Under rated conditions, the inverter draws a nominal current of 110 A; upstream breakers and busbars must be sized for that continuous load. During short bursts such as startup, the primary circuit can momentarily reach 800 A, and the downstream secondary winding can tolerate fault currents up to 36 kA before protective devices must interrupt the circuit. Cabinet thermal losses range from 100 W in standby to 200 W at full load, and these values support ventilation calculations when multiple inverters share one enclosure.

The power stage is designed for grid sources operating at 50/60 Hz, so no transformer is needed when the plant follows standard utility frequencies. Because the chassis is air-cooled, the ambient temperature around the heat sinks must remain at or below 45 °C, and a mounting clearance of 100 mm on all sides prevents airflow obstruction. Reliable operation is maintained at elevations up to 2000 m without derating, which covers most production sites outside extreme-altitude locations. The internal control section issues trigger pulses at a sequence frequency of 1000 Hz; this high switching rate minimizes ripple in the medium-frequency output used by connected coils. Installation requires 35 mm² supply conductors and 50 mm² terminal clamps. The 24 VDC stop circuit carries 3 A to ensure safe shutdown when an emergency stop signal is received.

Air-cooled Max Temp
45 °C
Cabinet Basic Loss
100 W
Cabinet Max Loss
200 W
Climatic category
3K3 according to EN 60721-3-3
Cooling Method
Air Cooled
Degree Of Protection
IP 20
Gasket Thickness
3 mm
Integrated power supply unit Output current
max. 2 A
Integrated power supply unit Output voltage
24 VDC
Mains frequency
50 or 60 Hz
Mains Nominal Current
110 A
Mains Voltage
480 - 690 VAC
Max Primary Current
800 A
Max Secondary Current
36 kA
Max. cooling losses
360 W
Mounting Clearance
100 mm
Operating Altitude
2000 m
Product Type
Medium Frequency Inverter
Required Cable Size
35 mm²
Sequence Frequency
1000 Hz
Stop Circuit Load
3 A
Stop Circuit Voltage
24 VDC
Supply Frequency
50/60 Hz
Temperature range Operation
+10 -+55 ºC
Temperature range Storage / transport
-25 - +70 ºC
Terminal Clamp Size
50 mm²
Timer Type
EtherNet
Weight
approx. 21 kg

Frequently Asked Questions about PSI63C0.757-L2:

Q: What is the mains voltage range for the PSI63C0.757-L2 frequency inverter?

A: The PSI63C0.757-L2 supports a mains voltage range of 480 to 690 VAC, allowing it to function in various industrial power environments.

Q: What is the maximum operating temperature for air-cooling on the PSI63C0.757-L2?

A: This inverter is designed for air-cooled operation with a maximum temperature of 45 °C.

Q: What is the maximum secondary current supported by the PSI63C0.757-L2?

A: The PSI63C0.757-L2 is rated for a maximum secondary current of 36 kA.

Q: What level of ingress protection does the PSI63C0.757-L2 provide?

A: The degree of protection for this model is IP20, offering limited protection against solid objects and no protection against liquids.

Q: How much mounting clearance is needed for the PSI63C0.757-L2?

A: A mounting clearance of 100 mm is required for proper installation of this inverter.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo