4.94 based on 219 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

PSI63C0.751-W1 Bosch Rexroth Indramat

Available
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The PSI63C0.751-W1 is a Bosch Rexroth Indramat medium frequency inverter built for 400 - 480 VAC systems with water-cooled thermal management. TriCore CPU architecture and Ethernet I/O support fast control response and straightforward network integration. IP20 protection and 110 A nominal mains current make the inverter a strong choice for demanding cabinet-based power applications.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The PSI63C0.751-W1 medium-frequency inverter is built by Bosch Rexroth Indramat and belongs to the PSI Frequency Inverters series. Designed for induction heating and other demanding automation tasks, the unit converts three-phase utility power into a programmable medium-frequency output that drives resonant transformer systems or work coils. By integrating power conversion, process control, and network interfacing in a single chassis, the inverter serves as the central energy source for equipment that requires precisely timed, high-current waveforms. Its architecture is intended for installations where compact power electronics must be placed inside machinery cabinets and connected directly to higher-level PLCs.

The incoming supply of 400–480 VAC is routed through a power stage with a nominal current draw of 110 A, and the internal TriCore CPU supervises waveform generation, protective interlocks, and timing. The electronic controls are enclosed in a housing with an IP20 degree of protection, so installation inside a sealed cabinet is required. For auxiliary devices, the inverter supplies 24 VDC at 2 A through its integrated power output, eliminating the need for a separate control transformer. Heat is extracted by a water-cooled cold plate. Cabinet losses reach 69 W at idle and 110 W under full load.

The power section can deliver up to 800 A of primary current, while the matching PSG 3100 transformer path can withstand peaks of 36 kA on the secondary, making it suitable for demanding heating cycles. Copper conductors with a minimum cross-sectional area of 35 mm² are required to carry these currents safely. During continuous operation, dynamic switching and reactive components raise total cooling losses to 420 W. Maintaining a water flow of 4 L/min keeps the pressure drop at 0.1 bar and prevents thermal derating. Control integration is handled through the built-in Ethernet I/O and an Ethernet-based timer module. The memory stores 256 selectable programs, allowing changeovers to be performed without external reconfiguration.

Cabinet Losses At Max %i
110 W
Cooling Method
Water Cooled
Cpu Type
TriCore
Degree Of Protection
IP20
I/o Connection
Ethernet
Integrated Power Output Current
2 A
Integrated Power Output Voltage
24 VDC
Mains Nominal Current
110 A
Mains Voltage
400 - 480 VAC
Max Cooling Losses
420 W
Max Primary Current
800 A
Max Secondary Current (psg 3100)
36 kA
Min Connection Cross-section
35 mm²
Min Cooling Water Flow
4 l/min.
Number Of Programs
256
Pressure Drop At 4 L/min.
0.1 bar
Product Type
Medium Frequency Inverter
Switch Cabinet Basic Losses
69 W
Timer Type
EtherNet

Frequently Asked Questions about PSI63C0.751-W1:

Q: What cooling method is used for the PSI63C0.751-W1 inverter?

A: The PSI63C0.751-W1 inverter uses a water cooling system for heat dissipation.

Q: What mains voltage does the PSI63C0.751-W1 support?

A: This inverter operates with a mains voltage range of 400 to 480 VAC.

Q: What is the maximum primary current for the PSI63C0.751-W1?

A: The maximum primary current supported by the PSI63C0.751-W1 is 800 A.

Q: What is the integrated power output of the PSI63C0.751-W1 inverter?

A: The integrated power output of this model is 24 VDC at 2 A for auxiliary devices.

Q: What is the minimum required cooling water flow rate for the PSI63C0.751-W1 inverter?

A: A minimum cooling water flow of 4 liters per minute is required for proper operation.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo