The Bosch Rexroth Indramat PSI6300.624L1 is a medium frequency inverter from the PSI Frequency Inverters series. It supports a line voltage of 400 to 480 VAC and operates at a mains frequency of 50 or 60 Hz. The inverter features air cooling, has an IP20 protection rating, and offers a nominal current of 110 Amps with a logic supply of 24 VDC.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The PSI6300.624L1 is a medium-frequency inverter manufactured by Bosch Rexroth Indramat as part of the PSI Frequency Inverters series. Its role in automation is to convert three-phase utility power into a regulated medium-frequency output that can drive induction heating coils, welding transformers, or other equipment requiring tight current control. The device resides in a ventilated cabinet and uses forced air movement to evacuate internal heat generated by the power electronics.
Input compatibility spans a line voltage of 400-480 V AC at the standard 50/60 Hz mains frequency. Under rated conditions the inverter conducts a nominal output current of 110 A, while the primary bus can tolerate momentary draws up to 800 A during start-up or load transients. Pulse-width modulation is performed at a carrier of 1 kHz, producing the medium-frequency waveform needed by downstream equipment without excessive switching loss. Control logic is sustained by a separate 24 VDC supply, and an internal auxiliary rail can source 2 A for sensors or contactors. Environmental ingress protection is limited to IP20, so the unit must be installed in a clean electrical enclosure with no direct dust or liquid exposure.
Thermal performance is managed by an air-cooling path that dissipates a basic cabinet loss of 69 W and handles a maximum cooling loss of 360 W when the drive is fully loaded. For safe wiring, the design specifies a minimum cable cross-section of 35 mm², a guideline that reflects the feeder capacity required to carry the maximum secondary current of 36 kA delivered by the output transformer stage. Operation is permissible up to an ambient temperature of 55 °C; beyond this point derating or external climate control is necessary. Additional integration features include DeviceNet timer support for coordinated sequencing and a logic-level interlock that disconnects the 24 V rail when mains power is absent.
Frequently Asked Questions about PSI6300.624L1:
Q: What line voltage is required for the PSI6300.624L1 frequency inverter?
A: The PSI6300.624L1 frequency inverter operates with a line voltage range of 400-480 V AC.
Q: What is the nominal current output of the PSI6300.624L1?
A: This model provides a nominal current output of 110 A for connected loads.
Q: What degree of protection does the PSI6300.624L1 offer?
A: The PSI6300.624L1 is designed with IP20 degree of protection, meaning it has limited protection against dust and no protection against liquids.
Q: What is the maximum ambient temperature the PSI6300.624L1 can operate in?
A: The maximum allowable ambient temperature for this inverter is 55 °C.
Q: What is the minimum cable cross-section needed for the PSI6300.624L1?
A: The minimum cable cross-section required for installation is 35 mm².