4.94 based on 219 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

PSI62C0.733-W1 Bosch Rexroth Indramat

Ask for Availability

Current response time:
5 Minutes 17 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat PSI62C0.733-W1 is a medium frequency inverter from the PSI Frequency Inverters series. It features a rated current of 220 A and operates with a mains voltage of 400 to 480 VAC. The inverter is water cooled, weighs 56 kg, and accommodates a maximum secondary current of 54 kA.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The PSI62C0.733-W1 is a medium frequency inverter built by Bosch Rexroth Indramat and assigned to the PSI Frequency Inverters series. As a power-conversion module, it transforms three-phase plant power into controlled medium-frequency output for induction heating coils, resistance-welding transformers, and similar automation loads that need rapidly adjustable energy delivery. By providing this intermediate power stage, the unit allows production machinery to modulate heat profiles or current densities without mechanical switching components, which improves cycle accuracy and supports closed-loop process control.

The inverter accepts a supply of 400 - 480 VAC, matching standard industrial mains. Under continuous conditions, it delivers 220 A, and the output can be modulated up to 1 kHz, which is suitable for medium-frequency heating tasks. Control signals are handled through a 24 VDC logic system that can source 2 A for external relays, while the integrated EtherNet timer synchronizes firing sequences with PLC commands. Cable lugs sized for a 95 mm² cross-section accommodate the required conductor ampacity. Thermal loading inside the enclosure starts at 69 W of basic cabinet loss and can rise to 700 W during maximum cooling operation. Even at full output, the cabinet still dissipates 210 W to ambient air, separate from the coolant circuit.

Water cooling removes the bulk of the switching heat. A minimum flow of 4 l/min keeps the plate temperature stable and produces a pressure drop of 0.6 bar at that rate. When heavy transient demands occur, the inverter can draw 1200 A on the primary side and pass up to 54 kA through the secondary circuit, so the liquid circuit also helps protect the copper busbars from thermal fatigue. The mechanical package measures 653 mm high, 288 mm wide, and 280 mm deep and weighs 56 kg. These dimensions allow direct installation in medium-power cabinets without special bracing.

Cabinet Basic Losses
69 W
Cabinet Losses At Max %i
210 W
Connection Cross-section
95 mm²
Cooling Method
Water Cooled
Depth
280 mm
Height
653 mm
Logic Output Current
2 A
Logic Output Voltage
24 VDC
Mains Voltage
400 - 480 VAC
Max Cooling Losses
700 W
Max Primary Current
1200 A
Max Secondary Current
54 kA
Min Water Flow
4 l/min
Primary Output Frequency
1 kHz
Product Type
Medium Frequency Inverter
Rated Current
220 A
Timer Type
EtherNet
Water Pressure Drop
0.6 bar at 4 l/min
Weight
56 kg
Width
288 mm

Frequently Asked Questions about PSI62C0.733-W1:

Q: What is the supported mains voltage for the PSI62C0.733-W1 frequency inverter?

A: The PSI62C0.733-W1 frequency inverter supports a mains voltage range from 400 to 480 VAC.

Q: What cooling method is used in the PSI62C0.733-W1 inverter?

A: This model employs a water-cooled method to manage heat during operation.

Q: What is the maximum secondary current of the PSI62C0.733-W1 inverter?

A: The PSI62C0.733-W1 can deliver a maximum secondary current of 54 kA.

Q: What is the water pressure drop at minimum flow rate for the PSI62C0.733-W1?

A: At 4 l/min of water flow, the water pressure drop is 0.6 bar for this inverter.

Q: What are the logic output voltage and current ratings for the PSI62C0.733-W1?

A: This inverter provides a logic output voltage of 24 VDC with a current capacity of 2 A.


Internal Product Review

  • ‘‘The PSI62C0.733-W1 is a Bosch Rexroth Indramat medium frequency inverter with water-cooled thermal management and a 220 A rated current. A 400 - 480 VAC mains range and 24 VDC logic output support straightforward integration into established industrial power systems. The 54 kA maximum secondary current is a standout specification for demanding process equipment.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo