4.94 based on 222 reviews

🙶 I have always received exceptional service and support in my many years of working with Wake Industrial. 🙷

PSI6100.630-W2 Bosch Rexroth Indramat

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The PSI6100.630-W2 is a medium frequency inverter with water-cooled thermal management for dependable duty cycles. Support for 480-690 VAC input and 50/60 Hz mains makes the unit well suited for demanding industrial power systems. The integrated 24 VDC power supply rated at 2 A adds practical control support and rounds out a very capable inverter platform.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The PSI6100.630-W2 medium-frequency inverter is produced by Bosch Rexroth Indramat and belongs to the PSI Frequency Inverters series. As a power conversion module, it supplies variable medium-frequency output to induction heating coils, high-speed spindle drives, and other equipment that uses programmable current and voltage profiles. Within an automation cell, the inverter connects the plant mains to the controlled load and coordinates energy delivery, while its integrated auxiliary supply powers sensors and control electronics. This arrangement reduces the need for separate power conversion and low-voltage supply components inside the control cabinet.

Its three-phase input section accepts line voltages from 480 to 690 VAC at mains frequencies of 50 or 60 Hz, allowing installation on standard high-voltage distribution networks. An internal 24 V auxiliary rail provides 24 VDC with a maximum output current of 2 A, so external relays and field devices can be powered without an additional supply. During operation, the water-cooled heat exchanger removes up to 420 W of power losses, helping keep semiconductor junctions within their safe temperature range and reducing heat accumulation in the cabinet. DeviceNet timing support enables coordinated startup with higher-level controllers. The water-cooling arrangement transfers heat away from sensitive power electronics without relying entirely on cabinet airflow.

The enclosure has an ingress protection rating of IP20, so the inverter must be mounted inside a switchgear cabinet that protects it from dust and dripping water. The permitted ambient temperature range of +10 to +55 °C supports continuous operation under typical machine-room conditions, while transportation and storage temperatures may range from -25 °C to +70 °C. Compliance with climatic class 3K3 under EN 60721-3-3 indicates suitability for moderate climatic conditions commonly found in production facilities. The unit weighs 25 kg, which limits the structural load placed on the mounting panel. Its enclosed design also helps prevent accidental contact with internal electrical components when it is correctly installed in a suitable cabinet.

Climatic category
3K3 according to EN 60721-3-3
Cooling Method
Water Cooled
Degree of protection
IP 20
Devicenet I/o Capacity
72 In, 72 Out
Integrated power supply unit Output current
max. 2 A
Integrated power supply unit Output voltage
24 VDC
Mains frequency
50 or 60 Hz
Mains Nominal Current
110 A
Mains Voltage
480 - 690 VAC
Max Electrodes
5
Max Installation Altitude
2000 m
Max Primary Current
400 A
Max secondary current
20 kA
Max. cooling losses
420 W
Min Cable Cross-section
35 mm²
Min Water Flow
4 L/min
Pressure Drop At 4 L/min
0.1 bar
Product Type
Medium Frequency Inverter
Program Capacity
256
Temperature range Operation
+10 -+55 ºC
Temperature range Storage / transport
-25 - +70 ºC
Terminal Capacity
50 mm²
Timer Type
Device Net
Weight
approx. 25 kg

Frequently Asked Questions about PSI6100.630-W2:

Q: What is the mains voltage range for the PSI6100.630-W2 frequency inverter?

A: This inverter operates at a mains voltage range of 480 to 690 VAC, supporting a wide array of industrial power systems.

Q: What type of cooling does the PSI6100.630-W2 frequency inverter use?

A: The cooling method used for the PSI6100.630-W2 is water cooling, helping manage higher thermal loads during operation.

Q: What are the output voltage and maximum output current of the integrated power supply unit in the PSI6100.630-W2?

A: This model provides an integrated power supply output voltage of 24 VDC with a maximum output current of 2 A.

Q: What level of protection does the PSI6100.630-W2 frequency inverter offer?

A: The degree of protection for the PSI6100.630-W2 is rated at IP20, ensuring protection against solid objects greater than 12.5 mm.

Q: What is the operational temperature range for the PSI6100.630-W2 frequency inverter?

A: The PSI6100.630-W2 operates within a temperature range of +10 to +55 °C for optimal performance.