4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

PPC-R22.1N-T-G2-P2-NN-FW Bosch Rexroth Indramat

MPN: R911309030

No Tariffs On US Orders
  • Rated 4.4 (53 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat PPC-R22.1N-T-G2-P2-NN-FW is a control unit from the PPC Controllers series, featuring a 4-digit alphanumeric display and an IP20 protection rating. It includes 3 digital inputs, 2 digital outputs, a Profibus fieldbus slave interface, and supports up to 40 drives. The unit has 3 expansion slots, onboard Ethernet, and operates at a supply voltage of 24 VDC with a maximum current of 1.2 A.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The PPC-R22.1N-T-G2-P2-NN-FW is a control unit produced by Bosch Rexroth Indramat for the PPC Controllers series. Mounted in centralized motion systems, it sequences axes, gathers machine signals, and links local drives with plant-level networks through its onboard communication ports. The integrated layout combines control, communication, and essential I/O in one enclosure, which helps reduce cabinet wiring and keeps related functions in a single hardware platform. In centralized machine architectures, it serves as the control point between field signals, coordinated axis commands, and supervisory data exchange. That role makes it suitable for systems where several motion axes and discrete machine signals must be managed from one location.

Operating from 24 VDC, the module draws up to 1.2 A. It has 3 digital inputs for sensor signals and 2 digital outputs for relay actuation, while the IP20 enclosure protects the terminals inside a cabinet. An input delay of 50 µs supports fast feedback handling, and the internal driver stage supplies 0.5 A per output without external amplifiers. The Profibus DPS01 slave interface transfers setpoints, onboard Ethernet provides access to parameters and network communication, and two serial ports support legacy devices. Input channels tolerate 24 V sensor power without dedicated isolators, and a grounding bar helps support EMC-compliant installation. This mix of power, I/O, and communication features allows the controller to interface with sensors, relays, networked drives, and older serial peripherals at the same time.

The controller supervises up to 40 drives. Each output reaches its new state within 500 µs, and DC bus conditioning limits ripple to 4 Vpp to reduce the chance of undervoltage faults during regeneration. A 4-digit alphanumeric display presents status codes for local diagnostics, and three expansion slots accept option cards for added functions such as high-speed counting. No memory expansion is installed, so those slots remain available for application-specific modules when needed. These operating limits support predictable timing in systems that coordinate multiple drives and machine signals.

Design Version
1
Digital Inputs
3
Digital Outputs
2
Display
4-Digit Alphanumeric
Expansion Slots
3
Fieldbus
Profibus fieldbus slave interface, DPS01
Housing Design
RECO unit
Input Delay
50 µs
Max Current
1.2 A
Max Drives
40
Memory Expansion
Not equipped
Onboard Ethernet
Yes
Output Current
0.5 A
Output Delay
500 µs
Product Type
Control Unit
Protection Rating
IP20
Ripple
4 Vpp
Serial Ports
2
Supply Voltage
24 VDC
  • PPCR22.1N-T-G2-P2-NN-FW
  • PPCR22.1NTG2P2NNFW
  • PPC R22.1N T G2 P2 NN FW

Frequently Asked Questions about PPC-R22.1N-T-G2-P2-NN-FW:

Q: How many digital inputs are available on the PPC-R22.1N-T-G2-P2-NN-FW controller?

A: The PPC-R22.1N-T-G2-P2-NN-FW controller has 3 digital inputs for integration with other control systems.

Q: What display type is found on the PPC-R22.1N-T-G2-P2-NN-FW control unit?

A: This unit features a 4-digit alphanumeric display for basic status and indication purposes.

Q: What fieldbus communication options does the PPC-R22.1N-T-G2-P2-NN-FW support?

A: The PPC-R22.1N-T-G2-P2-NN-FW is equipped with an onboard Profibus fieldbus slave interface, DPS01, for fieldbus communication.

Q: How many drives can be controlled by the PPC-R22.1N-T-G2-P2-NN-FW?

A: This controller supports a maximum of 40 drives for coordinated automation applications.

Q: What supply voltage does the PPC-R22.1N-T-G2-P2-NN-FW require?

A: The PPC-R22.1N-T-G2-P2-NN-FW operates with a supply voltage of 24 VDC for efficient power delivery.


Internal Product Review

  • ‘‘The PPC-R22.1N-T-G2-P2-NN-FW is a Bosch Rexroth Indramat control unit with onboard Ethernet and a Profibus fieldbus slave interface for efficient network integration. A 4-digit alphanumeric display and 3 expansion slots give the PPC controller strong diagnostic visibility and useful flexibility in machine control layouts. IP20 protection and support for up to 40 drives make the unit a highly capable choice for organized industrial control architecture.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo