4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

NAM4.2-480-0650-NN-120 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.6 (37 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
3 Minutes 4 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat NAM4.2-480-0650-NN-120 is part of the NAM Power Line Form Modules series. It operates with a control voltage of 120 VAC, a control frequency of 60 Hz, and supports a maximum module current of 650 Amps. The enclosure is rated IP00, with a max DC-link capacitance of 150 mF, and the unit weighs 20 kilograms.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The NAM4.2-480-0650-NN-120 is a power-line form module from the NAM Power Line Form Modules series manufactured by Bosch Rexroth Indramat. The unit is installed in multi-axis drive cabinets to shape and monitor the DC bus that supplies connected inverter modules for shared power distribution. By coordinating charging, preloading, and fault signaling, it supports stable energy management in industrial automation cells where regenerative drives and large surge currents are common.

This module is energized by a control line rated at 120 VAC and synchronized to a 60 Hz control frequency. Internal logic consumption remains limited to 15 VA, so auxiliary supplies can be sized modestly. A preload circuit delivers 1 A to charge capacitors gradually, while the recommended breaker size is 3.0 A to protect the control wiring. Once active, the power stage can conduct a maximum current of 650 A and buffer energy with a DC-link capacitance of 150 mF. The response relay inside the module is rated for 120 VAC at 1 A on AC loads and 24 VDC at 1 A on DC loads, allowing direct connection to interlock chains without external contactors. It is intended for 3K3 operating conditions, and the open IP00 enclosure means the cabinet must provide the necessary touch-safe barriers and airflow.

Power conductors are connected with a minimum cable section of 2 × 2 × 240 mm², and each terminal must be tightened to 35 Nm to maintain low impedance under high surge conditions. During short disturbances, the unit can withstand a transient pulse of 1000 VA for 150 ms without tripping, helping drive axes ride through line dips. The assembly weighs 20 kg, so the mounting plate must support that static load and keep the module secure during cabinet operation. Cable routing and terminal clamping must also allow enough space for the large conductors used on the power connections.

Control Frequency
60 Hz
Control Power
15 VA
Control Voltage
120 VAC
Enclosure Rating
IP00
Environmental Class
3K3
Max Dc-link Capacitance
150 mF
Max Module Current
650 A
Power Cable Min Section
2 x 2 x 240 mm²
Power Terminal Torque
35 Nm
Preload Output Current
1 A
Recommended Breaker
3.0 A
Response Contact Load (ac)
120 VAC / 1 A
Response Contact Load (dc)
24 VDC / 1 A
Transient Pulse
1000 VA for 150 ms
Weight
20 kg
  • NAM424800650NN120
  • nam4.2-480-0650-NN-120
  • NAM4 2 480 0650 NN 120

Frequently Asked Questions about NAM4.2-480-0650-NN-120:

Q: What is the maximum current supported by the NAM4.2-480-0650-NN-120 module?

A: The NAM4.2-480-0650-NN-120 is rated for a maximum module current of 650 A.

Q: What is the required control voltage for the NAM4.2-480-0650-NN-120?

A: This module operates with a control voltage of 120 VAC.

Q: What is the enclosure protection rating of the NAM4.2-480-0650-NN-120?

A: The enclosure carries an IP00 rating, meaning it is not protected against dust or moisture.

Q: What is the DC-link capacitance limit for the NAM4.2-480-0650-NN-120?

A: The maximum DC-link capacitance for this model is 150 mF.

Q: What size breaker is recommended for the NAM4.2-480-0650-NN-120?

A: The recommended breaker size for this unit is 3.0 A.


Internal Product Review

  • ‘‘The NAM4.2-480-0650-NN-120 is a Bosch Rexroth Indramat NAM power line form module that stands out for demanding drive applications, with 650 A maximum module current and 120 VAC control voltage. An IP00 enclosure rating and 150 mF maximum DC-link capacitance support dependable cabinet integration for high-capacity power sections.’’