The Bosch Rexroth Indramat NAM04.2-480-0450-NE-120 is part of the NAM Power Line Form Modules series and weighs 20 kilograms. This module operates with a maximum current of 450 amps and supports input voltages of 3-phase 380-480 V AC at 50 or 60 Hz. It features an IP00 enclosure and a max DC-link capacity of 150 millifarads.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The NAM04.2-480-0450-NE-120 is a power line form module manufactured by Bosch Rexroth Indramat within the NAM Power Line Form Modules series. It is installed at the front end of multi-axis drive cabinets to rectify and monitor incoming mains power before feeding a common DC link. The module also contains the control circuitry for its internal contactor and mains detection logic, and it is energized by a 120 V AC control supply so that switching and diagnostics remain active even when the main bus is de-energized.

The module accepts a three-phase input of 3 AC 380–480 V ±10 % at either 50 Hz or 60 Hz. Under those conditions the power section can conduct up to 450 A of line current while the control circuit draws only 15 VA. A short-term overload reserve of 1000 VA / 150 ms supports inrush demands during contactor closing. To pre-charge the link capacitors without tripping upstream protection, the preload circuit limits charging current to 1 A. When the main contactor is wired, its terminal screws must be tightened to 35 Nm, and the copper conductors feeding that device need a cross-section of 2 × 120 mm². The open-style IP00 housing is intended for mounting inside a finished electrical enclosure where ambient cooling air is directed across the heat-dissipating surfaces.

The DC bus that follows this module may be expanded to a maximum capacitance of 150 mF, allowing large energy buffers for heavy acceleration cycles. Protection on the control side is handled by the factory-installed Q1 breaker, rated at 1.6 A with a breaking capacity of 100 kA; its reference input is 1.1 A, while applications that demand additional margin can fit a recommended 3.0 A device. Automatic mains voltage detection eliminates manual range selection. The assembled unit weighs 20 kg, so cabinet supports must accommodate that static load without relying on the surrounding wiring for mechanical support.

Control Power
15 VA
Control Voltage
AC 120 V (±10%) 60 Hz
Enclosure
IP00
Input Voltage
3 AC 380-480 V (±10%) 50/60 Hz
Mains Voltage Detection
Yes
Max Current
450 A
Max Dc-link Capacity
150 mF
Power Contactor Min Cable
2 x 120 mm²
Power Contactor Torque
35 Nm
Preload Output Current
1 A
Pulse Power
1000 VA / 150 ms
Q1 Breaker Rating
1.6 A
Q1 Breaking Capacity
100 kA
Q1 Reference Input
1.1 A
Recommended Breaker
3.0 A
Weight
20 kg
  • NAM0424800450NE120
  • nam04.2-480-0450-NE-120
  • NAM04 2 480 0450 NE 120
  • NAM4.2-480-0450-NE-120

Frequently Asked Questions about NAM04.2-480-0450-NE-120:

Q: What input voltage range does the NAM04.2-480-0450-NE-120 module accept?

A: The NAM04.2-480-0450-NE-120 supports an input voltage of 3-phase 380 to 480 V AC with a tolerance of ±10% and frequencies of 50/60 Hz.

Q: What is the maximum current output of the NAM04.2-480-0450-NE-120?

A: This module provides a maximum current output of 450 A.

Q: Does the NAM04.2-480-0450-NE-120 include mains voltage detection?

A: The NAM04.2-480-0450-NE-120 features mains voltage detection.

Q: What is the Q1 breaker breaking capacity for the NAM04.2-480-0450-NE-120?

A: The Q1 breaker for this module has a breaking capacity of 100 kA.

Q: What type of enclosure does the NAM04.2-480-0450-NE-120 have?

A: The enclosure rating for the NAM04.2-480-0450-NE-120 is IP00.


Internal Product Review

  • ‘‘The NAM04.2-480-0450-NE-120 is a Bosch Rexroth Indramat power line form module designed for 3 AC 380-480 V input and rated for 450 A maximum current. AC 120 V control voltage and mains voltage detection support dependable integration in high-demand drive power sections. A 150 mF max DC-link capacity makes the unit a strong choice for stable power conditioning.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo