MTS-P02.2-D4-B1-P2-NN-NN-FW Bosch Rexroth Indramat
MPN: R911307530
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
3 Minutes
51 Seconds
The Bosch Rexroth Indramat MTS-P02.2-D4-B1-P2-NN-NN-FW is part of the MTS Servo Control Modules series and weighs 0.3 kilograms. It features RS232, RS422, and RS485 communication interfaces and supports up to 16 TTL digital inputs and 16 TTL digital outputs. The module can serve as an Interbus master for up to 512 users across a maximum distance of 12.8 km and also functions as a Profibus DP Slave at data rates up to 12 Mbaud.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The MTS-P02.2-D4-B1-P2-NN-NN-FW is a servo control module developed by Bosch Rexroth Indramat for the MTS Servo Control Modules series. Installed in a drive cabinet or control rack, it provides centralized processing and fieldbus routing so motion controllers, drives, and higher-level PLCs can exchange real-time data without bottlenecks. In typical industrial automation lines, the module synchronizes axes, forwards diagnostic telegrams, and connects legacy serial links with newer bus segments. This role makes it suitable for systems that need coordinated communication between motion hardware and supervisory control equipment.
The module supervises up to 4 BT Bus devices across a segment length of as much as 50 m. Local service access is available through the combined RS232/RS422/RS485 port, while machine signals are wired to the front panel’s 16 In / 16 Out TTL channels for fast switching tasks. Its compact size of 22×145×295 mm allows dense mounting beside amplifiers without using excessive cabinet space. When operating as the Interbus master, it can coordinate as many as 512 remote stations over twisted-pair or fiber connections. The Pc/104 backplane provides 2.5 A peak for stacked logic boards, and the logic rail does not exceed 1.8 A at +5 V, which helps keep power distribution straightforward. Ripple on the three DC rails is limited to 50 mV at +5 V and 120 mV on the ±12 V lines to help preserve stable data transfer.
Long-distance cell linking is possible because Interbus cabling can span 12.8 km with repeaters, while a dedicated Profibus channel exchanges cyclic data at up to 12 Mbaud and this unit operates strictly as a DP slave. That slave window supports 244 bytes in and 244 bytes out, which allows sizable parameter blocks to move during each scan cycle. The electronics are powered from a common ±12 V and +5 V supply identified as +5/+12/-12 VDC. Despite the communication density, the assembly weighs only 0.3 kg, which keeps the load on card guides low. This arrangement supports compact control racks where communication capacity and limited installation space both matter.
Frequently Asked Questions about MTS-P02.2-D4-B1-P2-NN-NN-FW:
Q: How many Bt Bus devices can the MTS-P02.2-D4-B1-P2-NN-NN-FW module support?
A: This module supports up to 4 Bt Bus devices for connection.
Q: What is the maximum Bt Bus cable length for the MTS-P02.2-D4-B1-P2-NN-NN-FW?
A: The maximum Bt Bus length for this module is 50 meters.
Q: Which communication interface options are available on the MTS-P02.2-D4-B1-P2-NN-NN-FW?
A: Supported communication interfaces are RS232, RS422, and RS485.
Q: How many digital I/O channels are provided by the MTS-P02.2-D4-B1-P2-NN-NN-FW?
A: This model provides 16 digital inputs and 16 TTL digital outputs.
Q: What supply voltages are needed for the MTS-P02.2-D4-B1-P2-NN-NN-FW module?
A: The supply voltage requirements are +5 VDC, +12 VDC, and -12 VDC.