MTS-P02.2-D2-P1-P2-E1-NN-FW Bosch Rexroth Indramat
MPN: R911307526
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
4 Minutes
53 Seconds
The Bosch Rexroth Indramat MTS-P02.2-D2-P1-P2-E1-NN-FW is part of the MTS Servo Control Modules series and measures 22 x 145 x 295 millimeters. This module operates at a maximum current of 1.8 Amps on the +5 V supply and supports up to four Bt Bus operator panels. Profibus communication is available with a data rate of 12 MBaud and diagnostic baud rate of 9600 baud.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The MTS-P02.2-D2-P1-P2-E1-NN-FW servo control module is produced by Bosch Rexroth Indramat within the MTS Servo Control Modules series. It plugs into an Indramat automation rack where it conditions low-voltage rails, supervises operator terminals, and exposes PROFIBUS links so drives and PLCs can exchange status and motion commands. By combining power management and fieldbus handling on a single board, the module reduces cabinet wiring and supports communication and supply monitoring for multi-axis systems in general factory automation.
The regulated +5 V supply feeds the module’s microcontrollers and I/O logic, and the rail can deliver up to 1.8 A to downstream boards. Signal quality is maintained by limiting ripple on this rail to 50 mV, which helps reduce jitter on high-speed counters. For deterministic plant networking, the onboard PROFIBUS interface transmits and receives telegrams at a maximum of 12 MBaud. The module measures 22 x 145 x 295 mm, matching the Eurocard format used in Rexroth drive racks. A header also supports up to four Bt Bus operator panels for local parameter entry and diagnostic viewing.
Separate analog rails of +12 V and -12 V supply sensors and interface couplers, and both are filtered to 120 mV ripple to protect conversion accuracy. When the drive controller must signal machine readiness, the isolated relay can switch 24 V / 150 mA, which removes the need for an external interface module. The electronics remain functional in ambient moisture up to 75% non-condensing, and the packaging tolerates transit levels of 95% non-condensing. Master-side communication is enabled by the PROFIBUS card LK DPM01, while installations that need only peripheral response can use the LK DPS01 slave card without changing the base hardware.
Frequently Asked Questions about MTS-P02.2-D2-P1-P2-E1-NN-FW:
Q: What is the maximum current capacity on the +5 V supply for the MTS-P02.2-D2-P1-P2-E1-NN-FW module?
A: The maximum current supplied on the +5 V line is 1.8 A.
Q: How many Bt bus operator panels can be connected to the MTS-P02.2-D2-P1-P2-E1-NN-FW control module?
A: This module supports up to four Bt bus operator panels simultaneously.
Q: What is the highest Profibus data rate supported by the MTS-P02.2-D2-P1-P2-E1-NN-FW module?
A: The module supports a maximum Profibus data rate of 12 MBaud.
Q: What is the maximum allowable operating humidity for the MTS-P02.2-D2-P1-P2-E1-NN-FW module?
A: This unit is designed to operate in environments with humidity up to 75% non-condensing.
Q: Which Profibus master module is compatible with the MTS-P02.2-D2-P1-P2-E1-NN-FW?
A: The MTS-P02.2-D2-P1-P2-E1-NN-FW uses the LK DPM01 as the Profibus master module.