MKE047B-144-KG0-BENN

MPN: R911299015

No Tariffs On US Orders
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The MKE047B-144-KG0-BENN Magnet Motor is manufactured by Bosch Rexroth Indramat. This motor has a 047 encoder and a shaft Plain Shaft (with sealing ring). This motor is Without Holding Brake

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The MKE047B-144-KG0-BENN Bosch Rexroth synchronous motor is designed for B05 flange assembly. The motor should not feature any pinching or jamming on the centering collar when it is mounted. The device comes with the SUP-M02-MKE accessory kit necessary for its connection. This unit must always be worked only after it has been disconnected and secured against restart. Its screwed connections must be capable of withstanding the forces because of the motor weight and the forces acting during operation. The product is highlighted by a length code of B. The device has an insulation class of 155 as per DIN EN 60034-1 specifications.

This synchronous motor is meant to be connected with the manufacturer’s readymade cables. The unit must always be cooled down for at least 140 minutes before the maintenance. The product should at all times be serviced or repaired only in the de-energized state and in a non-explosible atmosphere. The device offers high operational reliability. The motor can be utilized under adverse environmental conditions because of its completely closed design. The product also features data memory that makes the startup a fast and simple process. The device can be implemented in printing as well as packaging machines. The unit is transported through reputed logistics freight carriers.

The motor is not designed to be operated underwater at any point in time. The connectors of the device must neither be plugged in nor removed when the power is turned ON. The protective sleeves of the unit have to be removed only just before mounting. The motor does not have a holding brake. The housing of this product adheres to ATEX standards. The device features a sound pressure level of 63 +/-3 dBA. Faulty control of the device can result in dangerous movements of the associated drive. The motor with a year’s Wake Industrial warranty can be sent to any destination globally.

Continuous torque at standstill 60 K
2.7 Nm
Enclosure Protection
IP 65
Holding Brake
Without Holding Brake
Maximum current
22.6 A
Maximum torque
11.3 Nm
Maximum velocity
7000 rpm
Number of pole pairs
3
Sound pressure level
63 db(A)
Weight
5.5 kg
Winding inductivity
1.8 mH
  • MKE047B144KG0BENN
  • MKE047B 144 KG0 BENN
  • mke047b-144-kg0-benn
  • MKE47B-144-KG0-BENN
Typical drive message (ECODRIVE / DIAX) What it really means First things to check / do
F218 – Heatsink over-temperature shutdown Drive’s power-stage heatsink exceeded its limit  Let the unit cool, blow out dust, confirm cabinet fan/AC, replace failed fan if needed
F219 – Motor over-temperature shutdown Stator PTC tripped ≈ 155 °C  Reduce load, keep ambient ≤ 40 °C, clear dust on the flame-proof housing, verify temp-sensor wiring
F220 – Bleeder-resistor overload Dynamic-brake resistor overheated  Lengthen decel ramps, fit larger or forced-air bleeder, re-torque resistor wiring
E250 – Drive over-temperature warning Heatsink is hot but not yet at trip point  Improve ventilation before it escalates to F218; check cabinet cooling and airflow
F226 – DC-bus undervoltage Link voltage fell below minimum Check mains fuses, look for brown-outs, test DC-link capacitors and supply wiring
F228 – Excessive position deviation Command-vs-actual mismatch beyond window  Re-reference axis, tighten couplings, inspect mechanical backlash and encoder alignment
F230 – Encoder 1 max-frequency exceeded Motor-encoder signal too fast / noisy  Verify speed set-points, look for runaway axis, reroute or replace noisy feedback cable
F234 – Emergency-stop activated +24 V removed at E-Stop input, drive halted  Trace E-Stop circuit, reset safety relay, restore control-voltage feed, clear fault
F242 – Encoder 2 signal too small External sin/cos amplitude < 1 V  Check encoder-2 cable shielding, measure supply 5/12 V, replace faulty encoder if needed
F401 – Double MST error shutdown Two missed SERCOS master-sync frames  Clean fibre-optic links (attenuation < 12.5 dB), reseat transceivers, verify ring IDs
Model  Holding brake Encoder type Cont. torque (Nm) Max speed (rpm)
MKE047B-144-KG0-BENN No KG – multiturn, Hiperface (ID-memory) 2.7 7 000 
MKE047B-144-CP0-BENN No CP – multiturn absolute optical 2.7 7 000 
MKE047B-144-KG1-BENN Yes (2.2 Nm) KG  2.7 7 000 
MKE047B-144-CP1-BE0N Yes (2.2 Nm) CP absolute optical 2.7 7 000 
MKE047B-144-CG1-BUNN Yes (2.2 Nm) CG – optical absolute + parameter memory 2.7 9 000 
MKE047B-144-CP0-BUNN No CP absolute optical 2.7 7 000 
Error code Meaning
F218 Drive heatsink over-temperature shutdown 
F219 Motor over-temperature shutdown (PTC tripped) 
F220 Bleeder (braking-resistor) overload shutdown 
F221 Motor-temperature surveillance circuit defective (open/short) 
F226 DC-bus undervoltage in the power section 
F228 Excessive command-vs-actual position deviation 
F229 Encoder-1 failure: quadrant error 
F230 Max. signal frequency of encoder 1 exceeded (overspeed/noise) 
F234 Emergency-stop activated / +24 V removed at E-Stop input 
F242 Encoder-2 failure – signal amplitude too small 

Frequently Asked Questions about MKE047B-144-KG0-BENN:

Q: What are the primary applications for which this model can be used for?

A: The motor has been designed for various precision driven tasks and can also be used for paper manufacturing, processing, and printing applications. It is also suitable for use with packaging machines.

Q: Is the installation process straingtforward or requires prior expertise?

A: The installtion process in intutive and straightforward but it should be ensured that the motor is mounted without jamming or pinching of the centering collar.

Q: Is the motor provided with installtion accessories?

A: The MKE047B-144-KG0-BENN is provided with SUP-MO2-MKE accessory kit that is used for proper connection. This ensures a reliable and secure connection.

Q: Can the MKE047B-144-KG0-BENN be used with standard cables?

A: For reliable operation, it is recommended to use the manufacutring cables provided by the seller or the manufacturer of the motor.

Q: Is there any protection for the motor's internal wiring?

A: Yes, with the insulation class 155 according to DIN specifications, the motor's internal wiring remains protected against overheat.