4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

KDV 4.1-30-3-S1 Bosch Rexroth Indramat

MPN: R911258255

No Tariffs On US Orders
  • Rated 4.5 (49 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
5 Minutes 36 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDV 4.1-30-3-S1 is part of the KDV Supply Modules series and supports a link circuit DC voltage of 320 V with a peak power of 48 kW. The module has an auxiliary power input of 500 VA, cabinet power loss of 150 W, and can connect up to 10 drive modules. It weighs 21 kg and has a maximum overvoltage rating of 1490 V.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDV 4.1-30-3-S1 is a supply module manufactured by Bosch Rexroth Indramat for the KDV Supply Modules series. It delivers a stabilized DC link for coordinated servo axes, converts three-phase mains into a regulated internal bus, and provides a 24 V auxiliary rail for drive logic and safety relays. By combining energy distribution and braking circuitry in one housing, the unit simplifies cabinet wiring and supports automation lines that require simultaneous control of multiple drives. In multi-axis systems, this arrangement helps keep bus power available during coordinated motion and controlled braking events.

The module maintains a link circuit at 320 V DC and can momentarily furnish up to 48 kW to connected inverters during acceleration. Transient events are limited by a maximum overvoltage threshold of 1490 V, which protects drive electronics against mains spikes or regenerative peaks. The unit has an assembly weight of 21 kg, which is relevant for panel mounting and vibration loading. Cabinet power loss is 150 W; when combined with 500 W of external loss and the 70 VA drawn by each heatsink fan, these values indicate the required enclosure cooling capacity. The 24 V logic rail supplies 11.5 A with 2% ripple, while a separate 100 mA HSM output supports measurement circuitry. Auxiliary devices can draw 500 VA without affecting drive performance.

During regenerative braking, the internal bleeder can dissipate up to 40 kW, which is also the short-term limit for power returned from the drives. Absorption capacity reaches 100 kWs, allowing repeated deceleration cycles before external braking resistors are needed. A maximum of 10 drive modules can share the common DC bus, allowing several axes to operate from one supply unit. This layout suits installations where multiple servo amplifiers accelerate and decelerate on a shared power source. Continuous bleeder power is 0 W, so no heat is generated by the bleeder during steady-state operation.

24 Vl Current
11.5 A
24 Vl Ripple
2 %
Auxiliary Power Input
500 VA
Cabinet Power Loss
150 W
Continuous Bleeder Power
0 W
External Power Loss
500 W
Hsm Output Current
100 mA
Link Circuit Dc Voltage
320 V
Link Circuit Peak Power
48 kW
Max Drive Modules
10
Max Feedback Energy
100 kWs
Max Overvoltage
1490 V
Module Weight
21 kg
Peak Bleeder Power
40 kW
Peak Feedback Power
40 kW
Per Heat Sink Fan Power
70 VA
  • KDV 4.1 30 3 S1
  • KDV- 4.1-30-3-S1
  • KDV4.1303S1

Frequently Asked Questions about KDV 4.1-30-3-S1:

Q: How many drive modules can the KDV 4.1-30-3-S1 supply module support?

A: The KDV 4.1-30-3-S1 supply module can support up to 10 drive modules.

Q: What is the link circuit DC voltage of the KDV 4.1-30-3-S1?

A: This module has a link circuit DC voltage of 320 V.

Q: What is the maximum feedback energy handled by the KDV 4.1-30-3-S1?

A: The KDV 4.1-30-3-S1 has a maximum feedback energy rating of 100 kWs.

Q: What is the auxiliary power input requirement of the KDV 4.1-30-3-S1?

A: The auxiliary power input for this supply module is rated at 500 VA.

Q: What is the cabinet power loss for the KDV 4.1-30-3-S1 supply module?

A: This module produces a cabinet power loss of 150 W during operation.


Internal Product Review

  • ‘‘The KDV 4.1-30-3-S1 is a Bosch Rexroth Indramat supply module built around a 320 V DC link circuit and support for up to 10 drive modules. Peak power handling is impressive, with 48 kW link circuit peak power and 40 kW peak feedback power for demanding motion systems. A strong choice for multi-axis installations requiring stable power distribution and high transient capacity.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo