KDV 1.3-100-220/300-115V Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911220672
The Bosch Rexroth Indramat KDV 1.3-100-220/300-115V is part of the KDV Supply Modules series and has a rated current of 100 Amps and a nominal input voltage of 220 V AC. This module supports a DC bus voltage of 300 V DC, offers a 24 V load current of 8 Amps, and its type power is 30 kW. The unit weighs 21 kilograms and features a bleeder peak power of 40 kW.
Internal Product Review
The KDV 1.3-100-220/300-115V is a high-capacity supply module designed for dependable drive power conversion, with 220 V AC nominal input and a 300 V DC bus voltage. Rated output is especially strong for demanding systems, featuring 100 A rated current and 30 kW type power. Excellent energy handling adds further value, highlighted by 40 kW bleeder peak power and 60 kWs maximum feedback energy.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDV 1.3-100-220/300-115V is a supply module produced by Bosch Rexroth Indramat within the KDV Supply Modules series. In an automation cabinet, it converts incoming three-phase line power into a stabilized DC bus so that multiple servo drives receive the energy and auxiliary 24 V logic power needed for coordinated motion sequences. By integrating line rectification, bus charging, and regenerative dissipation in one assembly, the unit simplifies power distribution for grouped drive axes. This arrangement also allows several connected drives to share one common power source during synchronized machine movement.
This module accepts a nominal line of 220 V AC and can deliver a continuous output of 100 A onto the shared rails. Once rectified, the internal capacitors maintain a bus level of 300 V DC, which serves as the reference voltage for connected inverters. The internal transformer and heat sinks support a power rating of 30 kW, allowing machines with moderate total spindle and feed demand to run from a single source. Short acceleration bursts are handled by a peak current of 300 A for 300 ms without tripping the protective circuitry. To limit bus overvoltage during motor braking, the built-in bleeder resistor can absorb 2 kW continuously. This keeps returned energy from raising the DC bus beyond its normal operating range. A separate 24 V output provides 8 A for controller electronics, contactors, and sensor rails, removing the need for an external logic supply.
During emergency deceleration, the resistor tolerates a surge of 40 kW so kinetic energy is safely dumped instead of being returned to the line. The capacitors and resistor bank can accept up to 60 kWs of feedback energy before the monitoring circuit intervenes. Thermal modeling shows 150 W of heat remains inside the enclosure while 2000 W is expelled to the surrounding air, so cabinet ventilation must remove most of the operating heat load. Without field wiring and coolant plates, the unit weighs 21 kg, which provides a stable installed assembly while keeping handling manageable during mounting.