KDA 3.3-050-3-A0I-W1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.3-050-3-A0I-W1 is a spindle drive in the KDA Spindle Drives series and is designed with a forced cooling system using a mounted heatsink blower powered by a 220V AC source. It operates with a rated current of 50 Amps and a DC supply voltage of 300 VDC, and includes an incremental encoder output interface.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.3-050-3-A0I-W1 is a drive from the KDA Spindle Drives series built by Bosch Rexroth Indramat. Designed for machine-tool automation, it regulates the speed and torque of high-speed spindles while exchanging command and feedback data with the numerical control system in real time. By modulating a regulated DC bus, the unit delivers balanced three-phase power to synchronous or asynchronous spindle motors so machining processes can maintain constant surface speed, repeatable acceleration, and predictable cut quality. This operating role suits spindle-driven functions such as milling, drilling, and similar metal-cutting processes in automated machining centers and transfer lines.
The power section runs from a nominal bus of 300 VDC, and its output bridge is rated for continuous conduction at 50 A, which sets the continuous electrical operating range of the power stage. Thermal energy is removed through a mounted heat sink blower that uses 220 V at 50–60 Hz, and airflow is provided by forced cooling to keep semiconductor junction temperatures within design margins during sustained spindle loading. Installation is acceptable where ambient air remains between 5 to 45 °C; operation outside this range may trigger current derating. Cooling performance data remain valid up to 1000 m above sea level, where air density still supports the intended heat removal rate.
Control integration is based on a Series 3 hardware platform that receives the speed reference as an analog voltage or current signal. For position-related tasks, an auxiliary interface provides an incremental encoder output to the machine controller, allowing motion-related pulse information to be passed upstream. No provision exists for a second encoder input, so only the primary feedback loop is processed internally during spindle operation. This arrangement supports applications in which the controller supervises spindle-related motion data without relying on a separate internal feedback channel.
Frequently Asked Questions about KDA 3.3-050-3-A0I-W1:
Q: What is the rated current for the KDA 3.3-050-3-A0I-W1 spindle drive?
A: The KDA 3.3-050-3-A0I-W1 operates with a rated current of 50 A.
Q: How is the KDA 3.3-050-3-A0I-W1 spindle drive cooled?
A: This drive uses a mounted heatsink blower to provide forced cooling for its components.
Q: What is the ambient temperature range for the KDA 3.3-050-3-A0I-W1?
A: The KDA 3.3-050-3-A0I-W1 is designed to operate in ambient temperatures ranging from 5 to 45 degrees Celsius.
Q: What AC power requirements are needed for the heatsink blower on the KDA 3.3-050-3-A0I-W1?
A: It accepts an AC source for the heatsink blower at 220V and frequencies of 50-60Hz.
Q: What additional interface is available on the KDA 3.3-050-3-A0I-W1?
A: An incremental encoder output is provided as an additional interface with this spindle drive.