4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

KDA 3.2-150-3-AYI-W1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.4 (47 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.2-150-3-AYI-W1 is a spindle drive from the KDA Spindle Drives series with a rated current of 150 Amps and a DC supply voltage of 300 Volts. It features forced cooling with a mounted heatsink blower powered by a 220V AC source and is designed to operate in ambient temperatures from 5 to 45 degrees Celsius. This drive includes incremental encoder output and supports a second encoder input along with synchronous input.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.2-150-3-AYI-W1 is a spindle drive produced by Bosch Rexroth Indramat for the KDA Spindle Drives series and is version 2 of the third design release. In machining centers and grinding systems, this drive converts constant DC bus power into regulated three-phase output for high-speed spindle motors. That allows speed and torque control to follow programmable setpoints from the machine controller. Its role is to keep spindle behavior stable during changing cutting loads and speed commands in automated machine tools.

The drive is supplied from a common DC bus at 300 VDC, and its power electronics are rated for a continuous output of 150 A. These ratings describe the electrical supply and continuous current capacity of the unit while the devices on the DC link remain within thermal limits during normal operation. A mounted heatsink blower supports the unit’s forced cooling mode, and this blower is energized from an auxiliary source of 220 V 50–60 Hz. The airflow passes across the heatsink surfaces so the switching components can release heat during sustained spindle duty. When installed in cabinets kept between 5 to 45 °C, internal temperature sensors help keep semiconductor junction temperatures within their permitted range.

Signal handling is expanded by an incremental encoder output that retransmits spindle position data to external automation devices. The drive also provides a second encoder input with a synchronous capture channel for high-resolution feedback loops, which supports applications that require closely timed position information. Speed reference values arrive as an analog voltage, allowing direct compatibility with conventional CNC control cards. Installation is permitted up to 1000 m above sea level without current derating. The forced-air cooling hardware is integrated into the heatsink extrusion, so no separate ductwork is needed and cabinet layout stays straightforward.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
Incremental encoder output
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
150 A
Second Encoder Input
Second encoder input and synchronous input
Series
3
Series Version
2
Speed Command Value
Analogue
  • KDA 321503AYIW1

Frequently Asked Questions about KDA 3.2-150-3-AYI-W1:

Q: What is the rated current capability of the KDA 3.2-150-3-AYI-W1 spindle drive?

A: The KDA 3.2-150-3-AYI-W1 spindle drive has a rated current of 150 A, enabling it to power high-demand spindle applications.

Q: How is the KDA 3.2-150-3-AYI-W1 spindle drive cooled?

A: This drive uses a mounted heatsink blower for forced cooling, ensuring reliable thermal management during operation.

Q: What is the acceptable ambient temperature range for operating the KDA 3.2-150-3-AYI-W1?

A: The KDA 3.2-150-3-AYI-W1 operates within an ambient temperature range of 5 to 45 degrees Celsius.

Q: What power source is required for the heatsink blower on the KDA 3.2-150-3-AYI-W1?

A: The drive accepts an AC source for the heatsink blower of 220V at 50-60Hz.

Q: What encoder interfaces are provided by the KDA 3.2-150-3-AYI-W1 spindle drive?

A: Incremental encoder output and a second encoder input with synchronous input are available for enhanced feedback and control.


Internal Product Review

  • ‘‘The KDA 3.2-150-3-AYI-W1 spindle drive from Bosch Rexroth Indramat delivers excellent performance in demanding environments, featuring a rated current of 150 A and a 300 VDC supply voltage. Forced cooling is achieved with a mounted heatsink blower powered by a 220V AC source, supporting continuous operation within a 5 to 45 degrees Celsius ambient temperature range. The inclusion of incremental encoder output and a second encoder input enhances system flexibility and feedback precision, making this spindle drive a strong choice for high-performance spindle control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo