4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

KDA 3.2-150-3-A0I-W1/S001 Bosch Rexroth Indramat

MPN: R911254585

No Tariffs On US Orders
  • Rated 4.7 (16 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.2-150-3-A0I-W1/S001 is part of the KDA Spindle Drives series and is a spindle drive with a rated current of 150 Amps and a DC supply voltage of 300 VDC. It features forced cooling using a mounted heatsink blower powered by a 220V AC source at 50-60Hz and supports incremental encoder output.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.2-150-3-A0I-W1/S001 spindle drive is manufactured by Bosch Rexroth Indramat as part of the KDA Spindle Drives series. It is identified within that line as design 3 and version 2. In machine-tool cells, the unit energizes and regulates asynchronous or synchronous spindle motors during cutting, grinding, or drilling cycles. The drive is intended for applications where spindle response and steady rotation affect surface finish and process consistency. By converting a fixed DC bus into controlled three-phase output, it supports stable spindle speed during metal-removal operations and other continuous machining tasks.

It draws power from a bus that runs at 300 VDC, and its power section is rated for continuous armature currents up to 150 A, allowing it to energize large-frame spindles without derating. That current capacity suits spindle axes that need sustained torque during heavy cuts or repeated acceleration. Thermal control is maintained by forced cooling using a mounted heat sink blower fixed to the rear panel. Rear-mounted airflow removes heat from the power section without requiring liquid cooling hardware. The blower is supplied from an auxiliary source of 220 V/50–60 Hz, so no separate low-voltage fan circuit is required. Safe operation is specified from 5 to 45 °C when the enclosure climate remains within normal shop conditions.

On the control side, the drive generates an incremental encoder output that mirrors spindle position for downstream CNC controllers, yet it omits a secondary encoder input so only one feedback channel is processed internally. This arrangement fits control systems that rely on the drive for a single spindle feedback path. Velocity demand arrives as an analog speed command, allowing legacy machine controls to interface without fieldbus conversion. This input format suits retrofit installations where the existing control already provides a spindle reference signal. Installation is permitted up to 1000 m above sea level, provided ambient temperature and bus voltage stay within the stated limits.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
Incremental encoder output
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
150 A
Second Encoder Input
Does not feature additional input
Series
3
Series Version
2
Speed Command Value
Analogue
  • KDA 3.2 150 3 A0I W1/S001
  • KDA 3.21503A0IW1/S001
  • KDA- 3.2-150-3-A0I-W1/S001

Frequently Asked Questions about KDA 3.2-150-3-A0I-W1/S001:

Q: How is the KDA 3.2-150-3-A0I-W1/S001 spindle drive cooled?

A: The KDA 3.2-150-3-A0I-W1/S001 spindle drive operates with a forced cooling system using a mounted heatsink blower.

Q: What ambient temperature range can the KDA 3.2-150-3-A0I-W1/S001 operate within?

A: This spindle drive supports an ambient temperature range from 5 to 45 degrees Celsius.

Q: What is the rated current of the KDA 3.2-150-3-A0I-W1/S001 spindle drive?

A: The rated current for this model is 150 A, allowing high power output for demanding applications.

Q: What power supply is required for the heatsink blower on the KDA 3.2-150-3-A0I-W1/S001?

A: The spindle drive uses a 220V AC source at 50-60Hz specifically for the heatsink blower.

Q: What additional interface does the KDA 3.2-150-3-A0I-W1/S001 provide?

A: An incremental encoder output is included as an additional interface in this spindle drive.


Internal Product Review

  • ‘‘The KDA 3.2-150-3-A0I-W1/S001 is a Bosch Rexroth Indramat spindle drive with a 150 A rated current and analog speed command input. Forced cooling with a mounted heatsink blower supports stable thermal performance in continuous spindle applications. A 300 VDC supply and incremental encoder output make the unit especially attractive for precise, high-response drive control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo