KDA 3.2-100-3-LQD-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.2-100-3-LQD-U1 is a spindle drive from the KDA Spindle Drives series with a rated current of 100 Amps and a DC supply voltage of 300 VDC. It features forced cooling through a mounted heatsink blower powered by a 115V, 50-60Hz AC source, and operates in ambient temperatures from 5 to 45 degrees Celsius at elevations up to 1000 meters above sea level. The drive supports SERCOS interface for speed command value and has additional digital position command interfaces.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.2-100-3-LQD-U1 spindle drive is produced by Bosch Rexroth Indramat as part of the KDA Spindle Drives series, generation 3, version 2. Deployed between the machine control and a high-speed spindle motor, the unit converts DC bus energy into regulated three-phase output while exchanging setpoints and feedback with the motion controller. By doing so, it provides precise rotational velocity and torque regulation required for milling, drilling, and grinding centers that rely on tight spindle speed tolerances during machining cycles.
Its power section is sized for a continuous phase current of 100 A, allowing the connected motor to handle high cutting loads without entering current limit. The internal DC link is supplied by a common supply module at 300 VDC; this mid-level voltage balances response time with insulation demands on the stator windings. Thermal management is handled by a mounted heatsink blower that removes heat directly from the power semiconductors, and airflow is increased through forced cooling to keep junction temperatures stable during long duty cycles. The blower itself draws auxiliary power from a single-phase source rated at 115 V/50–60 Hz, simplifying cabinet wiring because no separate transformer is needed. Dynamic speed references are transmitted over the SERCOS interface, so the drive can be integrated into multi-axis networks that require deterministic communication and sub-millisecond update times. This communication path helps the spindle follow rapid command changes during acceleration, deceleration, and speed-holding intervals.
The drive operates properly only when the ambient air remains within 5 to 45 °C; outside this range, output derating or external conditioning is necessary. Installation altitude is limited to 1000 m above sea level because thinner air reduces cooling effectiveness and increases thermal stress on the blower. For orienting functions, a separate channel accepts a digital position command value, allowing the spindle to align its angular position during tool changes or orient cycles instead of relying only on speed control. This makes it suitable for machine sequences that require the spindle to stop at a repeatable angular location before the next operation begins.
Frequently Asked Questions about KDA 3.2-100-3-LQD-U1:
Q: What is the rated current for the KDA 3.2-100-3-LQD-U1 spindle drive?
A: The KDA 3.2-100-3-LQD-U1 has a rated current of 100 A.
Q: Which interface is used for speed command values on the KDA 3.2-100-3-LQD-U1?
A: This spindle drive uses a SERCOS Interface for speed command value input.
Q: How is the KDA 3.2-100-3-LQD-U1 drive cooled during operation?
A: Cooling is achieved by a mounted heatsink blower using forced cooling.
Q: What AC voltage is required for the heatsink blower on the KDA 3.2-100-3-LQD-U1?
A: The AC power source for the heatsink blower operates at 115V/50-60Hz.
Q: What is the maximum installation elevation for the KDA 3.2-100-3-LQD-U1 spindle drive?
A: The KDA 3.2-100-3-LQD-U1 can be installed at elevations up to 1000 meters above sea level.