KDA 3.2-100-3-L0S-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.2-100-3-L0S-U1 is part of the KDA Spindle Drives series and operates with a rated current of 100 Amps at a DC supply voltage of 300 Volts. This spindle drive uses forced cooling with a mounted heatsink blower powered by a 115V AC source at 50-60Hz and supports SERCOS speed command value. It features a serial RS 232 C interface and is designed to operate within a temperature range of 5 to 45 degrees Celsius, at a maximum elevation of 1000 meters above sea level.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.2-100-3-L0S-U1 spindle drive is produced by Bosch Rexroth Indramat and belongs to the KDA Spindle Drives series. Designed for closed-loop speed and torque regulation of high-speed machine tool spindles, it connects directly to a shared DC bus and communicates with CNC or PLC controllers. In automated equipment, it supplies controlled three-phase output to an attached motor while an integrated heat sink and dedicated blower remove thermal losses during continuous duty. It is intended for spindle applications that require stable rotation during drilling, milling, and similar machining processes.
Its power stage is energized from a shared DC link rated at 300 VDC. The drive can deliver a continuous phase output of 100 A, allowing it to accelerate large spindle masses without saturation. A separate auxiliary input of 115 V/50–60 Hz powers the blower, so cooling demand remains isolated from the main power bus. Because the unit operates from a common DC link, it can be used in systems where multiple axes share the same energy source. The cooling assembly uses a mounted heat sink blower, and airflow is provided through forced cooling. These features help keep semiconductor temperatures within acceptable limits during heavy cutting cycles and extended spindle operation.
The unit is rated for ambient temperatures from 5 to 45 °C and for mounting heights up to 1000 m above sea level, and operation outside those limits may require derating. Command values are transmitted over the SERCOS interface, enabling deterministic exchange of setpoints and status with motion controllers during synchronized spindle operation. Diagnostic tasks can be performed through the built-in serial interface (RS-232C), which provides a direct path for local communication. Because the design omits a second encoder input, feedback must be supplied through the primary spindle encoder, which simplifies wiring but limits dual-loop configurations.
Frequently Asked Questions about KDA 3.2-100-3-L0S-U1:
Q: What is the rated current capacity of the KDA 3.2-100-3-L0S-U1 spindle drive?
A: The KDA 3.2-100-3-L0S-U1 supports a rated current of 100 A, making it suitable for high-power spindle applications.
Q: How is the KDA 3.2-100-3-L0S-U1 spindle drive cooled?
A: This model uses a mounted heatsink blower for cooling with forced air to maintain optimal operating temperatures.
Q: What voltage and frequency does the heatsink blower of the KDA 3.2-100-3-L0S-U1 require?
A: The KDA 3.2-100-3-L0S-U1 accepts an AC source for the heatsink blower at 115V with a frequency of 50-60Hz.
Q: Which interface is used for speed command values on the KDA 3.2-100-3-L0S-U1?
A: This spindle drive communicates speed command values via a SERCOS Interface, ensuring precise control.
Q: What is the maximum installation elevation specified for the KDA 3.2-100-3-L0S-U1?
A: The KDA 3.2-100-3-L0S-U1 is rated for a maximum installation elevation of 1000 meters above sea level.