KDA 3.2-100-3-L0I-W1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.2-100-3-L0I-W1 is a spindle drive in the KDA Spindle Drives series with a rated current of 100 Amps and operates at a DC supply voltage of 300 VDC. It features forced cooling through a mounted heatsink blower powered by a 220V AC source, and supports a SERCOS Interface for speed command value. The unit includes an incremental encoder output and is designed to function within ambient temperatures of 5 to 45 degrees Celsius, at elevations up to 1000 meters above sea level.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.2-100-3-L0I-W1 spindle drive is produced by Bosch Rexroth Indramat as part of the KDA Spindle Drives series. It serves as a dedicated power stage for machine-tool spindles, converting shared DC-link energy into regulated phase currents while receiving motion commands from a CNC controller. This arrangement helps the spindle maintain stable speed during cutting, tapping, and grinding cycles. Direct torque control also helps the drive respond quickly to changing load conditions during machining. The unit is intended for installations where consistent spindle behavior is required across varying process demands.
This model has a rated output of 100 A, which suits medium-power spindle motors used on machining centers. The internal power section is supplied by a shared DC bus at 300 VDC, allowing energy exchange with other axes on the same supply. To remove switching heat, the housing uses a mounted heat sink blower for forced cooling. The blower is powered by an auxiliary supply of 220 V/50–60 Hz, so the cooling circuit remains independent of the drive's DC electronics. This arrangement helps maintain thermal stability in the power section during extended operating periods.
The velocity loop receives its setpoint through the SERCOS interface, and position data can be forwarded through the additional incremental encoder output when a controller requires real-time speed information. A second encoder socket is omitted, so no extra input is available for dual-loop configurations. Digital command transfer avoids the need for an analog speed reference and supports clean integration in multi-axis control cabinets. Reliable operation is specified for ambient temperatures from 5 to 45 °C and for mounting heights up to 1000 m above sea level. Operation outside these limits may require derating.
Frequently Asked Questions about KDA 3.2-100-3-L0I-W1:
Q: What is the rated current for the KDA 3.2-100-3-L0I-W1 spindle drive?
A: The KDA 3.2-100-3-L0I-W1 spindle drive operates with a rated current of 100 A.
Q: What cooling method is used in the KDA 3.2-100-3-L0I-W1?
A: This spindle drive uses a mounted heatsink blower with forced cooling for optimal temperature management.
Q: What additional interface does the KDA 3.2-100-3-L0I-W1 provide?
A: The drive supports incremental encoder output as an additional interface.
Q: Which interface is used for speed command value on the KDA 3.2-100-3-L0I-W1?
A: The SERCOS Interface is utilized for the speed command value in this model.
Q: What is the maximum installation elevation for the KDA 3.2-100-3-L0I-W1?
A: It is suitable for installation at elevations up to 1000 meters above sea level.