4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

KDA 3.2-100-3-L0D-U1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.5 (44 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.2-100-3-L0D-U1 is a spindle drive from the KDA Spindle Drives series with a rated current of 100 Amps and a 300 VDC supply voltage. It uses forced cooling through a mounted heatsink blower powered by a 115V AC source and supports speed command values via SERCOS Interface. This drive operates in ambient temperatures from 5 to 45 degrees Celsius and is suitable for installation up to 1000 meters above sea level.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.2-100-3-L0D-U1 spindle drive is manufactured by Bosch Rexroth Indramat for the KDA Spindle Drives series. As a servo inverter dedicated to high-speed spindles, it forms the link between a machine controller and the motor, shaping current and voltage so the cutting tool follows commanded profiles without lag. By accepting digital motion references and returning diagnostic data, the module allows CNC systems to coordinate spindle motion with feed axes during machining cycles. This arrangement helps the drive maintain stable torque delivery while protecting the spindle from thermal overload during continuous production.

The power section operates from a DC bus of 300 VDC and can deliver up to 100 A of phase current, giving headroom for aggressive spindle acceleration. Speed setpoints are transferred through a SERCOS interface, while fine contour corrections arrive on the separate digital position command value channel, reducing quantization error during finishing passes. The separated command paths support accurate speed regulation and fine path correction without mixing the two signals. The integral heat sink blower is energized from an auxiliary 115 V, 50/60 Hz source so the main drive supply remains undisturbed. This model does not provide a second encoder input for applications that use dual-loop feedback.

A mounted heat sink blower combined with forced cooling keeps component temperatures stable inside the cabinet. Cabinet airflow must remain unobstructed so heat can be removed effectively during extended spindle operation. The drive maintains rated performance when the ambient air is held between 5 to 45 °C, and no derating is required up to an altitude of 1000 m above sea level. These limits apply to the Series 3, Version 2 design revision. Above those conditions, excess heat or reduced air density can limit continuous current capability and trigger drive self-protection routines.

AC Source for Heatsink Blower
115V/50-60Hz
Additional Interfaces
Position command value, digital
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
100 A
Second Encoder Input
Does not feature additional input
Series
3
Series Version
2
Speed Command Value
SERCOS Interface
  • KDA 321003L0DU1

Frequently Asked Questions about KDA 3.2-100-3-L0D-U1:

Q: What is the cooling method for the KDA 3.2-100-3-L0D-U1 spindle drive?

A: The KDA 3.2-100-3-L0D-U1 spindle drive is cooled using a mounted heatsink blower for effective heat dissipation.

Q: What is the rated current of the KDA 3.2-100-3-L0D-U1 spindle drive?

A: This drive supports a rated current of 100 A, accommodating high-demand spindle applications.

Q: What AC source is needed for the heatsink blower of the KDA 3.2-100-3-L0D-U1?

A: The AC source required for the heatsink blower on this drive is 115V at 50-60 Hz.

Q: What is the ambient temperature range for operating the KDA 3.2-100-3-L0D-U1?

A: The environmental operating temperature for the KDA 3.2-100-3-L0D-U1 is between 5 and 45 degrees Celsius.

Q: What DC supply voltage does the KDA 3.2-100-3-L0D-U1 require?

A: This spindle drive accepts a DC supply voltage of 300 VDC.


Internal Product Review

  • ‘‘The KDA 3.2-100-3-L0D-U1 spindle drive from Bosch Rexroth Indramat features a rated current of 100 A and utilizes a forced cooling system with a mounted heatsink blower for dependable thermal management. The drive accepts position command values digitally and supports SERCOS interface for speed command input, providing modern connectivity. This spindle drive is well-suited for high-performance machining applications where precise control and cooling efficiency are required.’’