The KDA 3.2-100-3-DPD-U1 spindle drive operates with a rated current of 3.2 A, a rated voltage of 380-480 V, and an output power of 2.2 kW. Part of the KDA Spindle Drives series by Bosch Rexroth Indramat, it includes digital positioning control, encoder feedback, and panel mounting with an approximate weight of 7 kg.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.2-100-3-DPD-U1 Bosch Rexroth Indramat AC main spindle drive is intended only for industrial applications. This drive cannot be installed horizontally. The product is characterized by high stiffness. This device’s FAULT LED illuminates in red and its display flashes when a fault is encountered. The unit’s DC bus wiring has to be checked for a ground fault when the EARTH CON error code is highlighted on the display. Its ground bolt must be on the top with its upright mounting. This drive’s insertion must be done by using the long studs at the top and bottom of its housing.
The product-related programming module comprises the drive-specific data. This device has to be inserted into the opening above its heatsink blower. The unit houses a
This drive can share its power supply with several other drives. The product needs a control cabinet for its installation. This device weighs approximately 17.1 kg without its blower and accessories kit. The unit’s lifting action is to be accomplished with appropriate equipment. Its storage plus transportation temperature ranges from -30 °C to 85 °C. This main spindle drive must be properly grounded before it is turned on.
Frequently Asked Questions about KDA 3.2-100-3-DPD-U1:
Q: Why does the KDA 3.2-100-3-DPD-U1 drive need no reset when a replacement is needed?
A: The KDA 3.2-100-3-DPD-U1 drive needs no reset when a replacement is needed because its parameters and operating software are stored in the programming module.
Q: What is the maximum operating temperature of the KDA 3.2-100-3-DPD-U1 drive?
A: The maximum operating temperature of the KDA 3.2-100-3-DPD-U1 drive is 55 °C.
Q: How is the KDA 3.2-100-3-DPD-U1 drive cooled?
A: The KDA 3.2-100-3-DPD-U1 drive is cooled by a blower.
Q: Where are the long stud bolts of the KDA 3.2-100-3-DPD-U1 drive located?
A: The long stud bolts of the KDA 3.2-100-3-DPD-U1 drive are located at the top and bottom of its housing.
Q: What is the discharge time of the DC bus terminals of the KDA 3.2-100-3-DPD-U1 drive?
A: The discharge time of the DC bus terminals of the KDA 3.2-100-3-DPD-U1 drive is more than or equal to one minute.