KDA 3.2-100-3-D0S-U1

No Tariffs On US Orders
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The KDA 3.2-100-3-D0S-U1 spindle drive features a rated output current of 100 amps, an input voltage of 3x400 V AC ±10%, an overload capability of 150% for 60 seconds, and a switching frequency of 8 kHz. Part of the KDA Spindle Drives series by Bosch Rexroth Indramat, it utilizes forced air cooling.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Produced by the globally famous brand Bosch Rexroth Indramat, the variant KDA 3.2-100-3-D0S-U1 identifies as a main spindle amplifier built for machine tool integration. Its rated output current values 100 A which supplies ample drive current for heavy spindle loads and guarantees constant torque delivery. This spindle drive runs at a rated output voltage of 3 x 320 V and is 3-phased, to provide the required voltage levels for stable three-phase motor operation. Also, its input voltage is 3 x 400 V AC ±10%, allowing tolerance to supply fluctuations and supporting grid compatibility across industrial sites.

Input frequency maintains at 50/60 Hz that allows operations on both common industrial mains and global installations. Continuous output power is approximately 32 kVA which supports prolonged spindle operation under steady load and enables continuous machining cycles. The device’s switching frequency is 8 kHz and can yield fine PWM resolution for smoother torque control and reduced motor vibration. Utilizing forced air cooling with an internal fan further maintains thermal stability under sustained loads and prevents thermal trips. Protection class of IP20 indicates prevention against solid objects above 12 millimeters and for this reason it suits enclosed cabinet mounting.

Overload capability is 150% for 60 s that allows short bursts of high torque for machining transients and protects the system during intermittent peaks. Encoder interface supports TTL and SinCos, enabling flexible feedback options for precise speed and position control. Type code KDA 3.2-100-3-D0S-U1 lists fieldbus interface options including PROFIBUS and CANopen to allow networked control and integration with higher level automation. Weight of 35 kg facilitates in handling the equipment and rack planning for control cabinets. With a DC bus voltage of 300 V, the unit provides the drive energy buffer for dynamic torque demands and stabilizes DC link during rapid load changes.

Continuous Output Power
Approx. 32 kVA
Cooling Method
Forced air cooling (internal fan)
Encoder Interface
TTL / SinCos
Fieldbus Interface
Optionally PROFIBUS, CANopen
Input Frequency
50/60 Hz
Input Voltage
3 x 400 V AC ±10%
Overload Capability
150% for 60 s
Protection Class
IP20
Rated Output Current
100 A
Rated Output Voltage
3 x 320 V (three-phase)
Switching Frequency
8 kHz
Weight
Approx. 35 kg
  • KDA 321003D0SU1

Frequently Asked Questions about KDA 3.2-100-3-D0S-U1:

Q: What is the rated output current specification for KDA 3.2-100-3-D0S-U1 and how does it affect drive capability?

A: The module’s rated output current is 100 A which provides the amplifier with sufficient continuous current to handle heavy spindle loads and to maintain torque under high cutting forces.

Q: How does the rated output voltage specification for KDA 3.2-100-3-D0S-U1 influence motor drive compatibility?

A: The rated output voltage of 3 x 320 V three-phase for KDA 3.2-100-3-D0S-U1 matches common three-phase motor voltage requirements which ensures direct compatibility with standard industrial spindle motors.

Q: How does the input voltage range for KDA 3.2-100-3-D0S-U1 support installation flexibility?

A: The input voltage for the spindle drive is 3 x 400 V AC ±10% which accommodates typical industrial supply variations.

Q: How does the input frequency rating for KDA 3.2-100-3-D0S-U1 affect global deployment?

A: The input frequency rating of 50/60 Hz for KDA 3.2-100-3-D0S-U1 allows operation on both 50 Hz and 60 Hz mains which supports deployment across regions with different electrical grid standards.

Q: How does the continuous output power rating for KDA 3.2-100-3-D0S-U1 determine sustained machining capability?

A: The continuous output power of approximately 32 kVA for the component provides the energy throughput needed for extended machining runs.


Internal Product Review

  • ‘‘This industrial drive KDA 3.2-100-3-D0S-U1 combines a 100 A rated output with optional PROFIBUS/CANopen fieldbus which enables robust current delivery and networked control. The result is steady performance and simplified integration for demanding spindle applications.’’

Motion Industries logo