4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

KDA 3.2-100-3-D0I-W1 Bosch Rexroth Indramat

MPN: R911242788

No Tariffs On US Orders
  • Rated 4.4 (27 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.2-100-3-D0I-W1 is a spindle drive from the KDA Spindle Drives series and features a rated current of 100 Amps with a DC supply voltage of 300 Volts. It utilizes forced cooling with a mounted heatsink blower powered by a 220V AC source at 50-60Hz and supports a digital 16 bit parallel speed command value. The drive has an incremental encoder output and operates in ambient temperatures from 5 to 45 degrees Celsius.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.2-100-3-D0I-W1 belongs to the KDA Spindle Drives series produced by Bosch Rexroth Indramat. It is a spindle drive intended for closed-loop control of high-speed machining motors, providing regulated torque and speed to match numerical control commands. Within an automation cabinet, this unit serves as the power stage that links a DC bus to the motor windings while interfacing with the machine controller through a dedicated digital command port. This arrangement allows the controller to regulate spindle acceleration, steady-state speed, and load response during machining operations.

The drive is powered from a DC link at 300 V DC and can deliver a continuous motor phase current of 100 A. That current capacity supports sustained spindle loading in machining applications. An auxiliary AC feed of 220 V/50–60 Hz supplies the blower that maintains semiconductor temperature. The electronics are designed to operate in ambient air between 5 to 45 °C, so cabinet inlet air must stay within that range. Installation is permitted up to 1000 m above sea level without derating. Setpoints arrive through a 16-bit parallel digital command interface, allowing the numerical control to issue fine-resolution speed commands directly to the logic section.

Thermal management relies on a mounted heat sink blower, and airflow is directed across the fin stack by forced cooling so the internal power devices stay within their temperature limits during continuous machining cycles. Feedback can be forwarded to external motion controllers through an incremental encoder output, while a second encoder input is not included. This output can be used by higher-level control hardware for monitoring or coordination with related axes. The blower operates from the stated AC source, and intake filtering should be sized to limit debris buildup on the fins. The unit is Series 3, Version 2, and it uses the corresponding communication profile for KDA multi-axis racks.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
Incremental encoder output
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
100 A
Second Encoder Input
Does not feature additional input
Series
3
Series Version
2
Speed Command Value
Digital (16 bit parallel)
  • KDA 3.2 100 3 D0I W1
  • KDA 3.21003D0IW1
  • KDA- 3.2-100-3-D0I-W1

Frequently Asked Questions about KDA 3.2-100-3-D0I-W1:

Q: What type of cooling system is used in the KDA 3.2-100-3-D0I-W1 spindle drive?

A: The KDA 3.2-100-3-D0I-W1 spindle drive uses a mounted heatsink blower for forced cooling.

Q: How is the speed command value transmitted to the KDA 3.2-100-3-D0I-W1 spindle drive?

A: This model supports a digital speed command value through a 16 bit parallel interface.

Q: What is the rated current for the KDA 3.2-100-3-D0I-W1 spindle drive?

A: The rated current for the KDA 3.2-100-3-D0I-W1 is 100 A.

Q: What additional interface does the KDA 3.2-100-3-D0I-W1 spindle drive provide?

A: This spindle drive includes an incremental encoder output as an additional interface.

Q: What is the maximum installation elevation for the KDA 3.2-100-3-D0I-W1 spindle drive?

A: The KDA 3.2-100-3-D0I-W1 can be installed at elevations up to 1000 meters above sea level.


Internal Product Review

  • ‘‘The KDA 3.2-100-3-D0I-W1 spindle drive from Bosch Rexroth Indramat delivers a rated current of 100 A and features a 300 VDC supply voltage, making it suitable for high-demand spindle motor applications. Its forced cooling system with a mounted heatsink blower ensures stable performance within an ambient temperature range of 5 to 45 degrees Celsius. The digital 16-bit parallel speed command value and incremental encoder output highlight the drive's precision and integration potential for advanced industrial setups.’’