The Bosch Rexroth Indramat KDA 3.2-100-3-D00-W1 is a spindle drive in the KDA Spindle Drives series with a rated current of 100 Amps and a DC supply voltage of 300 Volts. It uses a mounted heatsink blower for forced cooling and operates in ambient temperatures from 5 to 45 degrees Celsius, supporting a maximum installation elevation of 1000 meters above sea level.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.2-100-3-D00-W1 is a spindle drive module from the KDA Spindle Drives series. This unit is series 3 and version 2 within the product line, and it is intended for common DC-bus systems used in CNC machining centers. It converts shared bus energy into controlled phase outputs for spindle motors, supporting accurate speed control during drilling, milling, and grinding. The drive also works with the machine control so spindle rotation can stay synchronized with feed-axis motion during cutting cycles. In a machining cell, this allows the spindle axis to follow programmed speed changes as tools enter or leave the workpiece.

This drive operates from a 300 VDC bus and can provide a continuous output of 100 A, helping the spindle respond to changing cutting loads without abrupt speed loss. Thermal energy is removed by a heatsink blower that uses forced cooling, which supports sustained operation when the spindle runs under prolonged load. The blower itself is powered by 220 V, 50–60 Hz and runs whenever the power stage is enabled. Speed command data reaches the control electronics as a 16-bit digital parallel word, giving the drive a precise setpoint format for closed-loop spindle regulation. Using a direct digital word helps avoid analog offset drift and preserves repeatable command resolution across the available speed range.

The unit is intended for ambient conditions from 5 to 45 °C and installation heights up to 1000 m. Outside that operating range, external cooling or power derating is required. The hardware includes no additional interface option, so it remains focused on core spindle-drive functions rather than optional network expansion. It also has no second encoder input, which means feedback handling is limited to the primary encoder path and the related command wiring stays direct. Because the expansion options are limited, the drive is suited to applications that rely on the standard control and feedback arrangement already provided by the base hardware.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
No Additional Interface Option
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
100 A
Second Encoder Input
Does not feature additional input
Series
3
Series Version
2
Speed Command Value
Digital (16 bit parallel)
  • KDA 3.2 100 3 D00 W1
  • KDA 3.21003D00W1
  • KDA- 3.2-100-3-D00-W1

Frequently Asked Questions about KDA 3.2-100-3-D00-W1:

Q: What cooling method is used on the KDA 3.2-100-3-D00-W1 spindle drive?

A: The KDA 3.2-100-3-D00-W1 spindle drive uses a mounted heatsink blower with forced cooling.

Q: What is the rated current capacity of the KDA 3.2-100-3-D00-W1 spindle drive?

A: This spindle drive operates with a 100 ampere rated current, supporting demanding spindle applications.

Q: What is the required DC supply voltage input for the KDA 3.2-100-3-D00-W1?

A: The KDA 3.2-100-3-D00-W1 accepts a DC supply voltage of 300 VDC.

Q: What type of speed command input does the KDA 3.2-100-3-D00-W1 support?

A: It features a speed command input that is digital and 16-bit parallel.

Q: What is the maximum installation elevation for the KDA 3.2-100-3-D00-W1 spindle drive?

A: This model is designed to be installed at elevations up to 1000 meters above sea level.


Internal Product Review

  • ‘‘The KDA 3.2-100-3-D00-W1 spindle drive from Bosch Rexroth Indramat features a rated current of 100 A and utilizes a forced cooling system with a mounted heatsink blower for optimal thermal management. With a 300 VDC supply voltage and digital (16 bit parallel) speed command value, this drive is well-suited for high-performance spindle control. Its design supports reliable operation within an ambient temperature range of 5 to 45°C.’’