- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.2-100-3-A0D-U1 is a spindle drive from the KDA Spindle Drives series with a rated current of 100 Amps and operates with a DC supply voltage of 300 Volts. It uses a mounted heatsink blower for forced cooling and can operate within ambient temperatures from 5 to 45 degrees Celsius. The drive supports digital position command value interfaces and features an analog speed command value input.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.2-100-3-A0D-U1 spindle drive is produced by Bosch Rexroth Indramat for the KDA Spindle Drives series. As a drive controller, it converts a fixed DC bus into variable three-phase output to run high-speed spindle motors used in machining centers, grinding cells, and other metalworking equipment. The unit integrates into Indramat multi-axis systems where coordinated spindle speed is required for precise cutting and tooling operations.
The drive operates from a DC link voltage of 300 VDC and can deliver up to 100 A of continuous output current, making it suitable for medium-to-large spindle applications. Thermal management uses a mounted heat-sink blower that pushes air across the power module, and airflow is supported by a dedicated 115 V/50-60 Hz auxiliary supply. Because the internal ducts rely on forced cooling, the unit can dissipate heat effectively during prolonged high-speed cuts. Speed reference data arrives as an analog voltage, while the machine CNC can also send a digital position command value through the additional interface when contouring accuracy is required. A second encoder input is not provided, so external phase-locked feedback devices must connect directly to the master controller. This variant is series number 3 and version 2 within the KDA family.
The drive maintains full ratings at ambient temperatures from 5 to 45 degrees Celsius, allowing it to share enclosures with other heat-generating axes without derating. Installation is permitted up to 1000 m above sea level, which covers most industrial sites without special cooling adjustments. The heat-sink blower draws filtered shop air, so particulate control in machining cells should suit this cooling method. These operating limits support stable current delivery and consistent command response during extended production use.
Frequently Asked Questions about KDA 3.2-100-3-A0D-U1:
Q: What is the rated current of the KDA 3.2-100-3-A0D-U1 spindle drive?
A: The KDA 3.2-100-3-A0D-U1 spindle drive operates with a rated current of 100 A.
Q: What cooling method does the KDA 3.2-100-3-A0D-U1 spindle drive use?
A: This model uses a mounted heatsink blower with forced cooling for optimal temperature regulation.
Q: What is the maximum installation elevation for the KDA 3.2-100-3-A0D-U1?
A: The KDA 3.2-100-3-A0D-U1 can be operated at installation elevations up to 1000 meters above sea level.
Q: What type of position command value interface does the KDA 3.2-100-3-A0D-U1 provide?
A: The spindle drive features a digital position command value interface for precise control requirements.
Q: What are the requirements for the AC source for the KDA 3.2-100-3-A0D-U1's heatsink blower?
A: The AC source for the heatsink blower requires 115V and supports both 50 Hz and 60 Hz frequencies.