KDA 3.2-050-3-LYI-W1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.2-050-3-LYI-W1 is a spindle drive from the KDA Spindle Drives series. It features forced cooling with a mounted heatsink blower powered by a 220V AC source, and is rated for a continuous current of 50 Amps. The drive supports a SERCOS interface for speed command value and includes additional incremental encoder output.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat builds the KDA 3.2-050-3-LYI-W1 for the KDA Spindle Drives series. Classified as a spindle drive, it regulates high-speed machine tool spindles by converting a constant DC bus into controlled three-phase power while exchanging velocity data over a fieldbus link. The 3.2 designation indicates the third series and second revision of this drive, which helps identify it within multi-axis machining systems.
The drive draws energy from a 300 VDC link and can deliver up to 50 A of continuous output current to the motor windings, allowing large-frame spindles to reach rated torque without derating. Thermal management relies on a mounted heat sink blower. Air is pushed through the fin stack by forced cooling so the power section maintains safe junction temperatures during long duty cycles. The control electronics remain operational from 5 to 45 °C, which matches the ambient range normally found in enclosed CNC cabinets. A SERCOS-formatted speed command is accepted through the fiber link, and internal logic forwards real-time position data to the controller. The unit also supports direct feedback redundancy through a second encoder connector and a synchronized trigger input for applications that compare two transducers.
The heat sink blower runs from a single-phase supply of 220 V/50-60 Hz, which simplifies power routing inside the panel. Communication is supported by a SERCOS interface telegram stream, while an auxiliary channel provides an incremental encoder output for downstream displays or external axis controllers. Installation is allowed up to 1000 m above sea level without current reduction, and altitude derating tables apply beyond that point. These interface options provide multiple signal paths for monitoring and control during variable-speed machining tasks.
Frequently Asked Questions about KDA 3.2-050-3-LYI-W1:
Q: What is the rated current specification for the KDA 3.2-050-3-LYI-W1 spindle drive?
A: The KDA 3.2-050-3-LYI-W1 spindle drive operates with a rated current of 50 A.
Q: What cooling method is used on the KDA 3.2-050-3-LYI-W1 spindle drive?
A: This spindle drive uses forced cooling through a mounted heatsink blower.
Q: What AC voltage and frequency does the heatsink blower require for the KDA 3.2-050-3-LYI-W1?
A: The AC source for the heatsink blower is 220V and supports 50-60Hz operation.
Q: How is the speed command value provided to the KDA 3.2-050-3-LYI-W1 spindle drive?
A: The KDA 3.2-050-3-LYI-W1 supports speed command input over a SERCOS interface.
Q: What is the allowable ambient temperature range for the KDA 3.2-050-3-LYI-W1?
A: This model operates within an ambient temperature range of 5 to 45 degrees Celsius.