4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

KDA 3.2-050-3-DYI-W1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.6 (23 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.2-050-3-DYI-W1 is part of the KDA Spindle Drives series and operates with a rated current of 50 Amps and a 300 VDC supply voltage. It uses a mounted heatsink blower for forced cooling and can function in environments with temperatures from 5 to 45 degrees Celsius. This spindle drive includes interfaces for incremental encoder output, second encoder input, and accepts digital speed command values.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.2-050-3-DYI-W1 spindle drive is manufactured by Bosch Rexroth Indramat and belongs to the KDA Spindle Drives series. As a dedicated spindle drive, it converts DC-link energy from an Indramat supply module into a controlled three-phase output for high-speed machine-tool spindles. The unit is Series 3 and Version 2, and it supports digital motion controllers that require precise torque regulation during milling, drilling, or grinding tasks in industrial automation. This output structure lets the spindle respond quickly to commanded speed and torque changes during demanding machining cycles.

Internally, the drive is energized from a 300 VDC intermediate circuit and can deliver a continuous phase current of 50 A, which suits medium-power spindle motors. Heat is removed by a mounted heat sink blower operating in Forced Cooling mode, and the fan receives power from a dedicated 220 V AC, 50–60 Hz supply so the main DC bus is not loaded. This arrangement separates blower power from the drive power section and keeps cooling available whenever the fan supply is present. Speed reference data enter the controller as a digital 16-bit parallel value, allowing fine resolution adjustments without analog drift. The blower is fixed directly to the rear plate and channels air across the IGBT stack and motor-field resistors to help maintain safe semiconductor temperatures during continuous service.

For field feedback and synchronization, the unit offers a second encoder input and an incremental encoder output that can be routed to the CNC control as auxiliary position channels. These interfaces support master-slave spindle arrangements, provide additional feedback paths for diagnostics, and can share spindle position data with external control functions. Rated operation is permitted within an ambient range of 5 °C to 45 °C, and cooling performance remains stable up to 1000 m of installation altitude without derating. Staying within this temperature and altitude range helps the drive avoid automatic current reduction that would lower available spindle torque.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
Incremental encoder output
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
50 A
Second Encoder Input
Second encoder input and synchronous input
Series
3
Series Version
2
Speed Command Value
Digital (16 bit parallel)
  • KDA 320503DYIW1

Frequently Asked Questions about KDA 3.2-050-3-DYI-W1:

Q: What AC voltage and frequency is required for the heatsink blower on the KDA 3.2-050-3-DYI-W1?

A: The KDA 3.2-050-3-DYI-W1 is designed for use with a 220V AC heatsink blower operating at 50-60Hz.

Q: What is the rated current supported by the KDA 3.2-050-3-DYI-W1 spindle drive?

A: This model supports a rated current of 50 A, allowing for substantial spindle drive power.

Q: How is the KDA 3.2-050-3-DYI-W1 spindle drive cooled?

A: Forced cooling is provided by a mounted heatsink blower to help maintain optimal temperature during operation.

Q: What is the function of the second encoder input on the KDA 3.2-050-3-DYI-W1?

A: The second encoder input enables connection of both a second encoder and synchronous input for improved feedback.

Q: What kind of speed command value interface does the KDA 3.2-050-3-DYI-W1 use?

A: The speed command value is received in a digital 16-bit parallel format in this spindle drive.


Internal Product Review

  • ‘‘The KDA 3.2-050-3-DYI-W1 spindle drive from Bosch Rexroth Indramat features a rated current of 50 A and operates with a 300 VDC supply voltage, delivering dependable performance for demanding spindle applications. Forced cooling with a mounted heatsink blower and support for 220V/50-60Hz AC source ensures continuous operation in environments up to 45°C. Incremental encoder output and a second encoder input make this unit an excellent choice for precise motion control.’’