4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

KDA 3.2-050-3-DY0-U1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.6 (66 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.2-050-3-DY0-U1 is a spindle drive from the KDA Spindle Drives series, designed with forced cooling using a mounted heatsink blower and supports an AC source of 115V at 50-60Hz. It operates with a rated current of 50 Amps, a DC supply voltage of 300 VDC, and supports digital 16-bit parallel speed command values. The drive supports ambient temperatures from 5 to 45 degrees Celsius and allows installation up to 1000 meters above sea level.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.2-050-3-DY0-U1 is produced by Bosch Rexroth Indramat and belongs to the KDA Spindle Drives series. It converts regulated DC-bus energy into three-phase output for machine-tool spindles, allowing the CNC control system to manage acceleration, braking, and steady-state speed. The unit is intended for spindle service in turning, grinding, and drilling equipment where rapid speed changes and stable rotation are required. When it is installed with matching supply and feedback modules in the same rack, the drive system remains compact and organized. This layout supports closed-loop spindle control in a centralized machine-drive assembly.

Its power section operates from a common link of 300 VDC and is rated for a continuous motor current of 50 A. The housing uses a mounted heat sink blower and forced cooling to remove heat from the output stage during repeated spindle acceleration and deceleration. The fan is powered by a dedicated 115 V/50-60 Hz source so airflow can continue independently of the DC link while residual heat leaves the power components. Speed commands are transmitted through a digital 16-bit parallel interface, which avoids analog drift and supports fine command resolution from the control. This combination of current capacity, directed airflow, and digital command input helps the drive maintain stable spindle response during changing machining loads.

The drive includes a second encoder input, which can be used for spindle-to-spindle synchronization or for additional position feedback checking. It operates in ambient temperatures from 5 to 45 °C, and installation is permitted at altitudes up to 1000 m above sea level before cooling capacity must be recalculated. The unit is Series 3 and Version 2. No additional interface option is installed, so the standard connection set remains unchanged. The blower, heat sink, and integrated thermal sensors help protect the switching devices during extended production runs.

AC Source for Heatsink Blower
115V/50-60Hz
Additional Interfaces
No Additional Interface Option
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
50 A
Second Encoder Input
Second encoder input and synchronous input
Series
3
Series Version
2
Speed Command Value
Digital (16 bit parallel)
  • KDA 320503DY0U1

Frequently Asked Questions about KDA 3.2-050-3-DY0-U1:

Q: What is the rated current output of the KDA 3.2-050-3-DY0-U1 spindle drive?

A: The KDA 3.2-050-3-DY0-U1 has a rated current of 50 A for spindle operation.

Q: How is the KDA 3.2-050-3-DY0-U1 spindle drive cooled?

A: This model features forced cooling provided by a mounted heatsink blower.

Q: What is the required DC supply voltage for the KDA 3.2-050-3-DY0-U1?

A: The spindle drive requires a 300 VDC supply voltage for operation.

Q: What is the maximum installation elevation for the KDA 3.2-050-3-DY0-U1?

A: The KDA 3.2-050-3-DY0-U1 can be installed at elevations up to 1000 meters above sea level.

Q: What format is used for speed command input on the KDA 3.2-050-3-DY0-U1?

A: This drive accepts digital speed command values in a 16-bit parallel format.


Internal Product Review

  • ‘‘The KDA 3.2-050-3-DY0-U1 is a spindle drive from Bosch Rexroth Indramat, designed for precision and reliability in demanding machine tool environments. With a rated current of 50 A and a DC supply voltage of 300 VDC, this unit handles high-performance spindle operations with ease. Forced cooling via a mounted heatsink blower ensures stable operation across the 5 to 45°C ambient temperature range.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo