The Bosch Rexroth Indramat KDA 3.2-050-3-AYI-U1 is a spindle drive from the KDA Spindle Drives series, designed with a rated current of 50 Amps and a DC supply voltage of 300 VDC. It uses a forced cooling system with a mounted heatsink blower powered by a 115V AC source and operates within an ambient temperature range of 5 to 45 degrees Celsius. The drive supports an incremental encoder output and offers second encoder and synchronous input options.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.2-050-3-AYI-U1 spindle drive is manufactured by Bosch Rexroth Indramat and belongs to the KDA Spindle Drives series. The unit serves as the power stage in automated machining centers, converting a regulated DC bus into controlled three-phase output for high-speed spindles. Because it is purpose-built for spindle control, it supports rapid speed transitions while its integrated cooling hardware preserves continuous duty in production environments. It is intended for machine tools that require controlled acceleration, deceleration, and stable speed regulation at the spindle. The output stage works with the machine control to keep commanded speed close to the requested value during changing cutting conditions.

Internally, the drive is powered from a DC link rated at 300 VDC. It delivers a continuous output of 50 A, enabling medium-power induction or synchronous spindles to accelerate quickly under load. Thermal stability is maintained by a mounted heat sink blower that directs air across the power modules. The blower is energized from a single-phase auxiliary supply of 115 V, 50–60 Hz, so no external converter is required. This forced-cooling arrangement keeps junction temperatures within limits provided the surrounding air remains within 5 to 45 °C. Series 3 electronics supervise these protections and handle fault reporting during operation.

The drive supports CNC feedback interfaces for spindle angle and speed control. An incremental encoder output transmits spindle angle to the motion controller, while a second encoder input and synchronous input permit dual-channel monitoring or master-slave coupling. This signal arrangement supports synchronized spindle functions that depend on accurate position exchange with the control system. Velocity commands arrive as an analog speed command value, making the drive compatible with conventional ±10 V control loops. Mechanical installation is permitted up to 1000 m above sea level, where the cooling system can still operate as intended.

AC Source for Heatsink Blower
115V/50-60Hz
Additional Interfaces
Incremental encoder output
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
50 A
Second Encoder Input
Second encoder input and synchronous input
Series
3
Series Version
2
Speed Command Value
Analogue
  • KDA 320503AYIU1

Frequently Asked Questions about KDA 3.2-050-3-AYI-U1:

Q: What type of cooling system does the KDA 3.2-050-3-AYI-U1 spindle drive utilize?

A: The KDA 3.2-050-3-AYI-U1 spindle drive uses a mounted heatsink blower for forced cooling.

Q: What is the rated current specification for the KDA 3.2-050-3-AYI-U1 spindle drive?

A: This spindle drive operates with a rated current of 50 A, supporting high-performance applications.

Q: What AC source does the heatsink blower of the KDA 3.2-050-3-AYI-U1 require?

A: The AC source for the heatsink blower is specified at 115V with a frequency range of 50-60Hz.

Q: What is the maximum installation elevation for the KDA 3.2-050-3-AYI-U1 spindle drive?

A: The maximum allowed installation altitude for this model is 1000 meters above sea level.

Q: What type of additional interface is provided on the KDA 3.2-050-3-AYI-U1 model?

A: An incremental encoder output is included as an additional interface on this spindle drive.


Internal Product Review

  • ‘‘The KDA 3.2-050-3-AYI-U1 spindle drive from Bosch Rexroth Indramat features a mounted heatsink blower with forced cooling, powered by a 115V AC source for reliable thermal management. It delivers a rated current of 50 A and operates with a 300 VDC supply voltage, making it well-suited for demanding spindle applications. The inclusion of a second encoder input and incremental encoder output enhances system feedback and control.’’