KDA 3.2-050-3-AY0-W1 Bosch Rexroth Indramat

MPN:

No Tariffs On US Orders
  • Rated 4.4 (54 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.2-050-3-AY0-W1 is a spindle drive from the KDA Spindle Drives series with a rated current of 50 Amps and a DC supply voltage of 300 VDC. It features forced cooling with a mounted heatsink blower powered by a 220V AC supply, and operates in ambient temperatures from 5 to 45 degrees Celsius. This drive includes a second encoder input with synchronous input and supports installation up to 1000 meters above sea level.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.2-050-3-AY0-W1 is a spindle drive module produced by Bosch Rexroth Indramat and assigned to the KDA Spindle Drives series. In a machining center or production cell, the unit converts DC bus power into a controlled three-phase output that regulates the rotational speed and torque of a motorized tool spindle. It processes analog command values, monitors motor feedback, and supports the stable spindle behavior needed for milling, drilling, grinding, and other continuous-duty tasks where speed regulation affects surface finish and tool performance. This arrangement also allows the CNC system to manage acceleration, deceleration, and spindle orientation as part of the larger machine sequence.

The intermediate circuit is stabilized at 300 VDC, and the power stage can deliver a continuous armature current of 50 A to the connected spindle motor, providing the electrical capacity required for sustained spindle loading. Thermal energy is removed through a mounted heatsink blower that uses its own 220 V/50–60 Hz supply, and the unit operates with forced cooling so heat can be carried away during long running periods inside an enclosure. Spindle speed is set through an analog reference channel, and a dedicated connector accepts a second encoder input together with a synchronous strobe for orientation functions, phase alignment, and coordination with external positioning devices.

The drive operates in ambient temperatures from 5 to 45 °C and can be installed up to 1000 m above sea level before additional cooling measures are needed. It has no additional interface option, so control wiring uses the standard I/O and feedback terminals already provided on the module. This keeps the electrical connection scheme limited to the built-in control and feedback paths rather than adding optional communication hardware. The product belongs to Series 3 and is manufactured in version 2.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
No Additional Interface Option
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
50 A
Second Encoder Input
Second encoder input and synchronous input
Series
3
Series Version
2
Speed Command Value
Analogue
  • KDA 320503AY0W1

Frequently Asked Questions about KDA 3.2-050-3-AY0-W1:

Q: What type of cooling is used in the KDA 3.2-050-3-AY0-W1 spindle drive?

A: The KDA 3.2-050-3-AY0-W1 spindle drive utilizes a mounted heatsink blower for forced cooling.

Q: What is the rated current of the KDA 3.2-050-3-AY0-W1 spindle drive?

A: This spindle drive supports a rated current of 50 A for its operational cycle.

Q: Does the KDA 3.2-050-3-AY0-W1 have a secondary encoder input?

A: It features a second encoder input and synchronous input for additional feedback options.

Q: What is the DC supply voltage required for the KDA 3.2-050-3-AY0-W1?

A: The drive operates with a DC supply voltage of 300 VDC.

Q: What is the maximum installation elevation for the KDA 3.2-050-3-AY0-W1?

A: The KDA 3.2-050-3-AY0-W1 can be installed at altitudes up to 1000 meters above sea level.


Internal Product Review

  • ‘‘The KDA 3.2-050-3-AY0-W1 spindle drive from Bosch Rexroth Indramat is engineered for demanding applications, delivering a rated current of 50 A and operating with a 300 VDC supply voltage. Forced cooling via a mounted heatsink blower ensures stable performance within ambient temperatures of 5 to 45 degrees Celsius. This drive is ideal for consistent, high-performance spindle control in industrial environments.’’