KDA 3.2-050-3-AQ0-W1 Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
The Bosch Rexroth Indramat KDA 3.2-050-3-AQ0-W1 is a spindle drive from the KDA Spindle Drives series. It features a forced cooling system using a mounted heatsink blower and operates with a rated current of 50 Amps. The drive supports a DC supply voltage of 300 VDC and can be used in ambient temperatures from 5 to 45 degrees Celsius.
Internal Product Review
The KDA 3.2-050-3-AQ0-W1 spindle drive from Bosch Rexroth Indramat delivers a solid 50 A rated current with a 300 VDC supply voltage, making it a strong performer for demanding spindle applications. Forced cooling is efficiently handled by a mounted heatsink blower operating on a 220V/50-60Hz AC source. This drive stands out for its stable operation within a 5 to 45 degrees Celsius ambient temperature range.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.2-050-3-AQ0-W1 is a spindle drive produced by Bosch Rexroth Indramat for the KDA Spindle Drives series. As a drive module, it supplies regulated three-phase power to high-speed machine tool spindles, translating velocity commands from a CNC or PLC into precise motor currents that help maintain torque under load. In typical use, the module supports stable spindle operation during cutting, drilling, and milling processes where demand can change quickly. The series 3 and version 2 codes identify the product generation within the KDA platform, which supports compatibility with companion supply units and feedback cards used in industrial machining centers and automated production cells.
The drive is energized from a DC bus rated at 300 VDC, allowing it to share a common supply with other Indramat axes. Under continuous operation, it can deliver 50 A of output current, providing sufficient current capacity for medium-frame induction or synchronous spindles. An auxiliary single-phase feed of 220 V/50-60 Hz powers the integral heatsink blower so thermal load is removed without taxing the main bus. Reliable function is maintained within an ambient range of 5 °C to 45 °C, which helps keep component temperatures stable on the factory floor. Installation altitude is limited to 1000 m above sea level because reduced air density lowers blower cooling performance.
Cooling hardware consists of a mounted heatsink blower that forces air through the fin stack, and this method is classified as forced cooling. Because the speed loop accepts an analog speed command, the unit can integrate directly with legacy control boards that output ±10 V references. The drive uses a standard terminal-strip interface, so diagnostic signals remain on fixed wiring connections rather than an added communication expansion port. This arrangement keeps control connections straightforward inside enclosed machine cabinets.