4.95 based on 202 reviews

🙶 I have always received exceptional service and support in my many years of working with Wake Industrial. 🙷

KDA 3.2-050-3-AP0-U1 Bosch Rexroth Indramat

MPN: R911232017

No Tariffs On US Orders
  • Rated 4.5 (48 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.2-050-3-AP0-U1 is a spindle drive from the KDA Spindle Drives series. It features forced cooling with a mounted heatsink blower and operates at a rated current of 50 Amps. The drive supports a DC supply voltage of 300 VDC and is suitable for use in ambient temperatures from 5 to 45 degrees Celsius.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.2-050-3-AP0-U1 spindle drive is produced by Bosch Rexroth Indramat as part of the KDA Spindle Drives series. It belongs to the 3.2 hardware generation within that series. The unit is supplied as a dedicated spindle controller for high-speed machining centers and similar industrial automation tasks where precise torque and speed regulation of motorized spindles is required.

This model operates from a DC bus of 300 VDC and can deliver a continuous output of 50 A to the connected spindle motor. Thermal energy is removed through a heat sink-mounted blower, and the blower is energized by an auxiliary source rated at 115 V, 50/60 Hz. Airflow is directed across the fins in a forced cooling mode to keep semiconductor temperatures within design limits during sustained cutting loads. Speed reference is accepted as an analog command voltage, allowing straightforward integration with conventional CNC controllers. No additional interface modules are fitted, so field wiring is limited to the standard power, control, and feedback terminals.

Permitted ambient temperature ranges from 5 to 45 °C, and installation can be performed at elevations up to 1000 m above sea level without derating. A dedicated secondary encoder input is provided, and this second encoder input can process spindle feedback or an extra motor transducer for synchronized axes. The drive’s cooling scheme depends on clean cabinet air, so forced ventilation should be maintained under all duty cycles. Because there is no additional interface option, auxiliary I/O must be routed through the main control rack instead of the drive housing. Analog speed references, combined with the 3.2 series hardware, give predictable dynamic response for threading, drilling, and contouring applications where constant surface speed is critical.

AC Source for Heatsink Blower
115V/50-60Hz
Additional Interfaces
No Additional Interface Option
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
50 A
Second Encoder Input
For spindle feedback or add. motor feedback
Series
3
Series Version
2
Speed Command Value
Analogue
  • KDA 3.2 050 3 AP0 U1
  • KDA 3.20503AP0U1
  • KDA- 3.2-050-3-AP0-U1

Frequently Asked Questions about KDA 3.2-050-3-AP0-U1:

Q: What is the rated current capacity of the KDA 3.2-050-3-AP0-U1 spindle drive?

A: The KDA 3.2-050-3-AP0-U1 spindle drive operates with a rated current of 50 A.

Q: How is the KDA 3.2-050-3-AP0-U1 spindle drive cooled?

A: This spindle drive uses a mounted heatsink blower and employs forced cooling for thermal management.

Q: What AC voltage and frequency does the heatsink blower of the KDA 3.2-050-3-AP0-U1 require?

A: The KDA 3.2-050-3-AP0-U1 accepts 115V/50-60Hz as the AC source for its heatsink blower.

Q: What is the maximum installation elevation for the KDA 3.2-050-3-AP0-U1?

A: This spindle drive is designed to be installed at elevations up to 1000 meters above sea level.

Q: What is the function of the second encoder input on the KDA 3.2-050-3-AP0-U1 spindle drive?

A: The KDA 3.2-050-3-AP0-U1 features a second encoder input for spindle feedback or additional motor feedback.


Internal Product Review

  • ‘‘The KDA 3.2-050-3-AP0-U1 spindle drive from Bosch Rexroth Indramat features a rated current of 50 A and uses a mounted heatsink blower for forced cooling. With a 300 VDC supply voltage and an ambient temperature range of 5 to 45 degrees Celsius, this unit is well-suited for demanding spindle applications. The inclusion of a second encoder input highlights its flexibility in feedback configuration.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo