4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

KDA 3.1-150-3-LQD-U1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.4 (34 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.1-150-3-LQD-U1 is a spindle drive in the KDA Spindle Drives series, featuring a rated current of 150 Amps and a DC supply voltage of 300 Volts. The drive uses forced cooling with a mounted heatsink blower powered by a 115V AC source and supports digital position command values as well as speed command through a SERCOS interface. It is designed to operate in ambient temperatures from 5 to 45 degrees Celsius and at elevations up to 1000 meters above sea level.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.1-150-3-LQD-U1 spindle drive is assembled by Bosch Rexroth Indramat for the KDA Spindle Drives series. It functions as a modular power stage that draws energy from a shared DC bus and energizes three-phase spindle motors used in CNC machining centers, turning stations, and grinding machines. By executing torque and velocity commands issued over fiber-optic links, the unit delivers precise rotational control that is essential for maintaining surface finish, dimensional accuracy, and short cycle times within automated production lines.

Electrical ratings dominate the hardware description of revision 3. The drive can deliver a continuous output of 150 A, enabling direct connection to large-frame induction or synchronous spindle motors without derating. Its power stage is supplied from a 300 VDC link that is normally produced by an Indramat supply module; regulation circuits monitor this bus to prevent over-current or under-voltage trips. Thermal stability is maintained by a mounted heatsink blower that is fed from a separate 115 V 50/60 Hz AC source. Airflow through the fins is arranged as forced cooling, so internal component temperatures stay within design limits even during prolonged heavy roughing passes. Together these parameters define the maximum power envelope available to the spindle while adhering to the protection objectives of Series 3 hardware.

Interface and environmental data complete the operating profile. Speed references arrive through a SERCOS interface, and separate axis-level corrections can be injected over a digital position command interface when tighter contour control is required. The drive performs to specification in ambient air between 5 to 45 °C, provided installation height does not exceed 1000 m above sea level; outside these limits additional derating is necessary. These limits ensure the blower can evacuate heat effectively and that the control electronics maintain signal integrity under nominal air density and temperature conditions.

AC Source for Heatsink Blower
115V/50-60Hz
Additional Interfaces
Position command value, digital
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
150 A
Series
3
Speed Command Value
SERCOS Interface
  • KDA 311503LQDU1

Frequently Asked Questions about KDA 3.1-150-3-LQD-U1:

Q: What is the rated current output of the KDA 3.1-150-3-LQD-U1 spindle drive?

A: The KDA 3.1-150-3-LQD-U1 provides a rated current output of 150 A, supporting demanding spindle drive applications.

Q: What cooling method does the KDA 3.1-150-3-LQD-U1 spindle drive use?

A: A mounted heatsink blower is used for cooling, which relies on forced air to maintain optimal operating temperatures.

Q: What is the required DC supply voltage for the KDA 3.1-150-3-LQD-U1 spindle drive?

A: This spindle drive accepts a DC supply voltage of 300 VDC for its power requirements.

Q: What interface is used for speed command input on the KDA 3.1-150-3-LQD-U1?

A: The speed command value is communicated via a SERCOS interface, enabling precise digital communication with controllers.

Q: What is the highest recommended installation elevation for the KDA 3.1-150-3-LQD-U1?

A: The maximum installation elevation for this spindle drive is 1000 meters above sea level.


Internal Product Review

  • ‘‘The KDA 3.1-150-3-LQD-U1 is a spindle drive from Bosch Rexroth Indramat featuring a rated current of 150 A and a DC supply voltage of 300 VDC, making it suitable for high-demand spindle applications. Forced cooling is handled by a mounted heatsink blower powered at 115V/50-60Hz, ensuring reliable thermal management. The inclusion of SERCOS interface for speed command value provides excellent integration with modern automation systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo