KDA 3.1-150-3-DYD-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.1-150-3-DYD-U1 is a spindle drive from the KDA Spindle Drives series with a rated current of 150 Amps and a DC supply voltage of 300 Volts. It uses forced cooling via a mounted heatsink blower powered by a 115V AC source and operates in ambient temperatures from 5 to 45 degrees Celsius. This drive includes digital position command value interfaces and supports a second encoder input with synchronous capability.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-150-3-DYD-U1 is a spindle drive module produced by Bosch Rexroth Indramat and part of the KDA Spindle Drives series. It converts regulated DC-link energy into three-phase output for high-speed motorized spindles used in CNC machining centers and turning machines. Internal logic accepts digital reference data from the machine controller, while a mounted heat sink blower removes switching losses produced under heavy load. This arrangement supports stable spindle control during cutting, drilling, and other speed-sensitive machining operations. In an automation cell, the drive maintains commanded spindle speed and torque so machining accuracy stays within tolerance.
The power section draws 300 VDC from the common supply bus and can deliver a continuous output of 150 A, giving it enough margin to accelerate large spindle motors without derating. Thermal energy is removed through a blower powered by an auxiliary source rated at 115 V/50–60 Hz, which keeps airflow constant during regenerative events. The drive uses forced cooling, so heat sink temperature is controlled by active air movement rather than passive convection. Motion commands arrive as a 16-bit digital parallel speed word, allowing the numerical control to set precise rotational velocity in one bus cycle.
The drive may be mounted at elevations up to 1000 m above sea level. Reliable operation is permitted only between 5 to 45 °C, so the panel must stay within that ambient range during use. For multi-axis machines, the module provides a second encoder input and a synchronous input, enabling phase-aligned feedback from tandem spindles or external master encoders. A dedicated channel for the digital position command value lets the controller transmit incremental moves directly for tapping, orient, or rigid tool-change sequences without analog conversion.
Frequently Asked Questions about KDA 3.1-150-3-DYD-U1:
Q: What is the rated current for the KDA 3.1-150-3-DYD-U1 spindle drive?
A: The KDA 3.1-150-3-DYD-U1 spindle drive has a rated current of 150 A to support high-performance motor operation.
Q: What cooling method does the KDA 3.1-150-3-DYD-U1 spindle drive use?
A: This spindle drive utilizes forced air cooling via a mounted heatsink blower.
Q: What is the required AC source for the KDA 3.1-150-3-DYD-U1 heatsink blower?
A: A 115V, 50-60Hz AC source is required for the heatsink blower of this spindle drive.
Q: What is the maximum installation elevation for the KDA 3.1-150-3-DYD-U1?
A: The maximum permitted installation elevation for this spindle drive is 1000 meters above sea level.
Q: What type of speed command input does the KDA 3.1-150-3-DYD-U1 support?
A: The KDA 3.1-150-3-DYD-U1 has a digital 16-bit parallel speed command value input for precise control.