KDA 3.1-100-3-L0D-W1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.1-100-3-L0D-W1 is part of the KDA Spindle Drives series and is a spindle drive with a rated current of 100 Amps and a DC supply voltage of 300 VDC. It uses forced cooling via a mounted heatsink blower powered by a 220V AC source, and supports a SERCOS interface for speed command values and digital position command values. The operating ambient temperature range is 5 to 45 degrees Celsius, and the maximum installation elevation is 1000 meters above sea level.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-100-3-L0D-W1 is a spindle drive module manufactured by Bosch Rexroth Indramat within the KDA Spindle Drives series. It supplies three-phase power to high-speed spindle motors. It also interprets numerical control commands to regulate acceleration, speed, and braking during machining cycles in industrial automation. This lets the module serve as the power and control stage between the machine control and the spindle motor in applications that need stable speed behavior during cutting and deceleration.
This drive operates from a DC bus of 300 VDC and can furnish a continuous output of 100 A to the connected spindle motor, giving the motion system a broad torque reserve. Thermal management relies on a mounted heat sink blower that is powered from a separate 220 V at 50/60 Hz line, so cabinet airflow does not have to cool the power electronics directly. Because the blower is attached to a dedicated heat sink, the cooling path is concentrated at the semiconductors that generate the most heat. The assembly uses forced cooling to keep semiconductor temperatures below their rated limits. The unit is Series 3 and communicates its velocity target through the SERCOS interface, allowing synchronous updates with other axis drives on the same fiber-optic ring.
The permitted ambient range is 5 to 45 °C, which suits typical factory installations without supplemental chillers. The unit may be installed up to 1000 m above sea level before output derating applies. Command flexibility is improved by a digital position command input, which lets an external motion controller pass precise positional data to the spindle. The spindle section omits a secondary encoder channel, so that connection can be reserved for other feedback functions elsewhere in the machine. This layout is useful where the control system separates spindle speed regulation from higher-level position handling.
Frequently Asked Questions about KDA 3.1-100-3-L0D-W1:
Q: What AC source is required for the heatsink blower of the KDA 3.1-100-3-L0D-W1?
A: The KDA 3.1-100-3-L0D-W1 uses a 220V, 50-60Hz AC source specifically for its heatsink blower.
Q: What is the rated current output of the KDA 3.1-100-3-L0D-W1 spindle drive?
A: This spindle drive provides a rated current of 100 A, supporting high current requirements in industrial applications.
Q: What cooling method is implemented in the KDA 3.1-100-3-L0D-W1?
A: It uses forced cooling with a mounted heatsink blower to manage internal temperatures during operation.
Q: What operating temperature range is specified for the KDA 3.1-100-3-L0D-W1?
A: The ambient temperature range for reliable operation is from 5 to 45 degrees Celsius.
Q: How does the KDA 3.1-100-3-L0D-W1 receive its speed command values?
A: Speed command values for this drive are received via the SERCOS Interface protocol.