KDA 3.1-100-3-L00-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.1-100-3-L00-U1 is a spindle drive from the KDA Spindle Drives series with a rated current of 100 Amps and operates on a DC supply voltage of 300 VDC. It uses a forced cooling mode with a mounted heatsink blower running on 115V at 50-60 Hz, and is designed to function within an ambient temperature range of 5 to 45 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-100-3-L00-U1 is a spindle drive module produced by Bosch Rexroth Indramat and assigned to the KDA Spindle Drives series. It is installed between the mains rectifier and the motor to regulate torque and speed for high-speed machining spindles in automated production cells. The unit belongs to the third design release of the family and provides closed-loop drive control, while the heat sink blower uses a separate AC supply for continuous thermal management. This arrangement helps the module respond to load changes during spindle acceleration, deceleration, and steady cutting operation.
Internally, the power section is energized from a DC bus of 300 VDC. Under continuous duty, the drive can deliver a rated phase current of 100 A, so the matching motor and cabling must be sized accordingly. Thermal losses are removed by a mounted heat sink blower, and the unit uses forced cooling to keep semiconductor junctions within their allowable temperature range during heavy acceleration cycles. The blower itself operates from an auxiliary source of 115 V/50-60 Hz, so the control cabinet needs a single-phase supply branch for that circuit. Because there is no additional interface option and no second encoder input, wiring is simpler but multi-feedback configurations are not available.
The drive operates at ambient temperatures from 5 to 45 °C without derating. Installation is permitted up to 1000 m above sea level, allowing use at standard plant elevations before reduced air density affects cooling. Speed reference data arrives digitally through the SERCOS interface, enabling synchronized motion commands with other axis controllers in networked machines. The unit is part of Series 3, and the absence of extra option cards reduces enclosure depth and helps airflow around the chassis. Digital command transmission also supports applications where spindle speed must follow coordinated machine sequences.
Frequently Asked Questions about KDA 3.1-100-3-L00-U1:
Q: What is the rated current capacity of the KDA 3.1-100-3-L00-U1 spindle drive?
A: The KDA 3.1-100-3-L00-U1 supports a rated current of 100 A.
Q: How is the KDA 3.1-100-3-L00-U1 spindle drive cooled during operation?
A: This drive utilizes a mounted heatsink blower, providing forced cooling for efficient heat management.
Q: What power supply is necessary for the KDA 3.1-100-3-L00-U1’s heatsink blower?
A: The AC source for the heatsink blower requires 115V at 50-60Hz.
Q: What speed command value interface comes with the KDA 3.1-100-3-L00-U1?
A: For speed command input, this model is equipped with a SERCOS interface.
Q: What is the maximum allowable installation elevation for the KDA 3.1-100-3-L00-U1?
A: It can be installed at elevations up to 1000 meters above sea level.