The Bosch Rexroth Indramat KDA 3.1-100-3-DY0-W1 is a spindle drive from the KDA Spindle Drives series, featuring a forced cooling mode with a mounted heatsink blower that operates at 220V and 50-60Hz. It works with a DC supply voltage of 300 VDC, has a rated current of 100 Amps, and supports digital 16-bit parallel speed commands along with a second encoder input for synchronization. The drive operates in ambient temperatures from 5 to 45 degrees Celsius and can be installed up to 1000 meters above sea level.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.1-100-3-DY0-W1 is a spindle drive produced by Bosch Rexroth Indramat within the KDA Spindle Drives series. Designed for panel-mounted machine tool spindles, the unit converts fixed DC bus energy into precisely regulated three-phase output for speed and torque control. By accepting digital speed commands from the motion controller, it serves as the regulating element between the CNC system and the asynchronous or synchronous motor used in milling, drilling, and similar automation tasks. It is intended for industrial automation systems that require repeatable spindle performance over a broad speed range.

For its power stage, the drive operates from a DC bus of 300 VDC, which supplies the inverter section with enough headroom to generate high spindle frequencies. The drive has a continuous output current rating of 100 A, allowing sustained operation without derating. A dedicated heat sink blower is wired to 220 V/50-60 Hz, so airflow is maintained whenever the electronics are active. Environmental limits permit operation between 5 to 45 °C, which helps determine cabinet climate conditions. Installation is permitted up to 1000 m above sea level. The control card is supplied without an additional interface option, which reduces unused connectors and simplifies wiring to the master controller.

A mounted heat sink blower forces air directly across the power modules, and forced cooling helps limit internal temperature rise during sustained duty. Speed reference data reach the drive through a 16-bit parallel digital input, providing fine resolution over the commanded speed range. This format supports accurate transfer of commanded values from the higher-level control without relying on analog scaling. For feedback verification, the unit includes a second encoder input and a synchronous input so the spindle encoder signal can be compared with an auxiliary sensor during operation. The drive is in series 3, which identifies its product generation within the KDA range.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
No Additional Interface Option
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
100 A
Second Encoder Input
Second encoder input and synchronous input
Series
3
Speed Command Value
Digital (16 bit parallel)
  • KDA 311003DY0W1

Frequently Asked Questions about KDA 3.1-100-3-DY0-W1:

Q: What is the rated current of the KDA 3.1-100-3-DY0-W1 spindle drive?

A: The rated current for the KDA 3.1-100-3-DY0-W1 spindle drive is 100 A.

Q: What cooling method is used for the KDA 3.1-100-3-DY0-W1 spindle drive?

A: The KDA 3.1-100-3-DY0-W1 uses a mounted heatsink blower, providing forced cooling for thermal management.

Q: What is the required DC supply voltage for the KDA 3.1-100-3-DY0-W1?

A: The drive is operated with a DC supply voltage of 300 VDC.

Q: What is the maximum installation elevation for the KDA 3.1-100-3-DY0-W1?

A: The device allows a maximum installation elevation of up to 1000 meters above sea level.

Q: How is the speed command value transmitted to the KDA 3.1-100-3-DY0-W1 spindle drive?

A: The speed command value for this model is received in digital format with a 16 bit parallel interface.


Internal Product Review

  • ‘‘The KDA 3.1-100-3-DY0-W1 is a spindle drive from Bosch Rexroth Indramat equipped with a 100 A rated current and digital 16-bit parallel speed command input for precise motion control. Forced cooling with a mounted heatsink blower ensures steady operation within an ambient temperature range of 5 to 45 degrees Celsius. This model stands out for dependable performance in demanding spindle applications.’’