KDA 3.1-100-3-DY0-W1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.1-100-3-DY0-W1 is a spindle drive from the KDA Spindle Drives series, featuring a forced cooling mode with a mounted heatsink blower that operates at 220V and 50-60Hz. It works with a DC supply voltage of 300 VDC, has a rated current of 100 Amps, and supports digital 16-bit parallel speed commands along with a second encoder input for synchronization. The drive operates in ambient temperatures from 5 to 45 degrees Celsius and can be installed up to 1000 meters above sea level.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-100-3-DY0-W1 is a spindle drive produced by Bosch Rexroth Indramat within the KDA Spindle Drives series. Designed for panel-mounted machine tool spindles, the unit converts fixed DC bus energy into precisely regulated three-phase output for speed and torque control. By accepting digital speed commands from the motion controller, it serves as the regulating element between the CNC system and the asynchronous or synchronous motor used in milling, drilling, and similar automation tasks. It is intended for industrial automation systems that require repeatable spindle performance over a broad speed range.
For its power stage, the drive operates from a DC bus of 300 VDC, which supplies the inverter section with enough headroom to generate high spindle frequencies. The drive has a continuous output current rating of 100 A, allowing sustained operation without derating. A dedicated heat sink blower is wired to 220 V/50-60 Hz, so airflow is maintained whenever the electronics are active. Environmental limits permit operation between 5 to 45 °C, which helps determine cabinet climate conditions. Installation is permitted up to 1000 m above sea level. The control card is supplied without an additional interface option, which reduces unused connectors and simplifies wiring to the master controller.
A mounted heat sink blower forces air directly across the power modules, and forced cooling helps limit internal temperature rise during sustained duty. Speed reference data reach the drive through a 16-bit parallel digital input, providing fine resolution over the commanded speed range. This format supports accurate transfer of commanded values from the higher-level control without relying on analog scaling. For feedback verification, the unit includes a second encoder input and a synchronous input so the spindle encoder signal can be compared with an auxiliary sensor during operation. The drive is in series 3, which identifies its product generation within the KDA range.
Frequently Asked Questions about KDA 3.1-100-3-DY0-W1:
Q: What is the rated current of the KDA 3.1-100-3-DY0-W1 spindle drive?
A: The rated current for the KDA 3.1-100-3-DY0-W1 spindle drive is 100 A.
Q: What cooling method is used for the KDA 3.1-100-3-DY0-W1 spindle drive?
A: The KDA 3.1-100-3-DY0-W1 uses a mounted heatsink blower, providing forced cooling for thermal management.
Q: What is the required DC supply voltage for the KDA 3.1-100-3-DY0-W1?
A: The drive is operated with a DC supply voltage of 300 VDC.
Q: What is the maximum installation elevation for the KDA 3.1-100-3-DY0-W1?
A: The device allows a maximum installation elevation of up to 1000 meters above sea level.
Q: How is the speed command value transmitted to the KDA 3.1-100-3-DY0-W1 spindle drive?
A: The speed command value for this model is received in digital format with a 16 bit parallel interface.